2000-Sheet Dual Input (Ttm)-Sensor (Tray 4 Feed-Out) Removal - Lexmark X940e Service Manual

Hide thumbs Also See for X940e:
Table of Contents

Advertisement

7510-XXX
2000-sheet dual input (TTM)—sensor (tray 4 feed-out) removal
1. Remove the media tray 2 assembly.
2. Remove the tray module left cover. See
page
4-164.
3. Remove the TTM media tray 3 assembly. See
removal" on page
4. Remove the TTM media tray 4 assembly. See
removal" on page
5. Disconnect the connector from the sensor (tray 4 feed-out) (A).
6. Release the hooks securing the sensor (tray 4 feed-out) (A) to the upper guide (B).
7. Remove the sensor (tray 4 feed-out) (A).
4-178
MFP Service Manual
"2000-sheet dual input (TTM)– tray module left cover removal" on
4-168.
4-167.
Connector
A
Hook
Front
"2000-sheet dual input (TTM)–TTM media tray 3 assembly
"2000-sheet dual input (TTM)–TTM media tray 4 assembly
B

Advertisement