Step
10
Check the inverter solenoid assembly for proper
operation.
Caution: When performing motor tests,
ensure that all cover and door interlock
switches are overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Scanner Motor Tests.
4. Touch Inverter solenoid.
Does the above component operate properly?
11
Check the inverter solenoid assembly for proper
connection.
Is the above component properly connected?
12
Check the ADF registration motor for proper operation.
Caution: When performing motor tests,
ensure that all cover and door interlock
switches are overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Scanner Motor Tests.
4. Touch ADF registration drv mtr.
5. Touch Forward or reverse.
Does the above component operate properly?
13
Check the ADF registration motor for proper connection.
Is the above component properly connected?
14
Place an undamaged document in the ADF, and perform
a ADF test.
Does the error remain?
Check
Yes
Go to step 12.
Go to step 11.
Replace the
Replace the
inverter
connection.
solenoid
assembly.
Go to
"Inverter
solenoid
assembly
removal" on
page
4-136.
Go to step 14.
Go to step 13.
Replace the
Replace the
ADF
connection.
registration
motor.
Go to
"ADF
registration
motor
removal" on
page
4-156.
Replace the
Problem solved.
ADF controller
card assembly.
Go to
"ADF
controller card
assembly
removal" on
page
4-135.
Go to step 15.
Diagnostic information
7510-XXX
No
2-81

Advertisement

Table of Contents
loading

This manual is also suitable for:

X945e mfp

Table of Contents