Step
2
Check the CMYK PC cartridge drive motor assembly for
proper operation.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Printer Motor Tests
4. Touch K PC cartridge drive motor.
Does the above component operate properly?
3
Check the CMYK PC cartridge drive motor assembly for
proper connection.
Is the above component properly connected?
4
Perform a POR.
Does the error occur when the power is turned off/on?
903.02 CMY PC drive motor error
Step
1
Perform a POR.
Does the error occur when the power is turned off/on?
2
Check the CMYK PC cartridge drive motor assembly for
proper operation.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Printer Motor Tests
4. Touch CMY cartridge drive motor
Does the above component operate properly?
Check
Caution: When performing motor tests,
ensure that all cover and door interlock
switches are overridden.
Check
Caution: When performing motor tests,
ensure that all cover and door interlock
switches are overridden.
Yes
Go to step 4.
Go to step 3.
Replace the
Replace the
CMYK PC
connection.
cartridge drive
motor assembly.
Go to
"CMYK PC
cartridge drive
motor assembly
removal" on
page
4-88.
Replace the lower
Problem solved.
printer engine card
assembly.
Go to
"Lower
printer engine
card assembly
removal" on
page
4-77.
Yes
Go to step 2.
Perform several
print tests.
If the problem
remains, go to
step 2.
Go to step 4.
Go to step 3.
Diagnostic information
7510-XXX
No
No
2-131