For example, Let's assume that E.164 called number is 82(02)3438-4968.
In the office, call is made possible by pressing number 14968, which is the
extension number of the telephone. If users set destination-pattern with
'82023438' in outbound POTS dial peer which is associated with the
telephone, termination GW strips '82023438'after receiving call with
82(02)3438-4968. For terminating GW to make possible call with the
pertinent destination, put '1' in front of the remaining digit. To do this,
configuration should be done like the following.
dial-peer voice pots 20
destination-pattern 82023438....
prefix 1
port 0/1/1:2
Forward Digits
''forward-digits' command regulates the number of digit stripped before
dialed string transmitted to the other telephony device. Generally, outbound
POTS dial peers strips the entire digit matchable specifically with destination-
pattern and transmits only the matchable digit in wildcard pattern. 'Forward-
digits' command transmits the entire digit or the fixed number of digit among
dialed digit regardless of the number of digit matchable clearly with
destination pattern.
'Forward-digits' command is supported in only POTS dial peer.
For example; 'forward-digits 3' command intends to transmit the last three
digits of dialed string. 'Forward-digits all' command intends to transmit the
entire dialed string. 'Forward-digits all' command intends to transmit the
entire part when the length of dialed digit is larger than that of destination-
pattern. In the case that destination-pattern of dial-peer is variable-length such
as '3438...T' and '3438T', it is impossible to transmit.