Samsung Ubigate iBG2016 Configuration Manual page 531

Hide thumbs Also See for Ubigate iBG2016:
Table of Contents

Advertisement

Ubigate iBG2016 Configuration Guide/Ed.00
Cadence
To define the tone-on and tone-off duration for a call-progress tone, use the
cadence command in call-progress dualtone configuration mode.
Configure>voice class custom-cptone tag dualtone busy cadence {cycle-1-on-
time cycle-1-off-time [cycle-2-on-time cycle-2-off-time] [cycle-3-on-time
cycle-3-off-time] [cycle-4-on-time cycle-4-off-time]}
cycle-1-on-time - Tone-on duration for the first cycle of the cadence pattern,
in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-1-off-time - Tone-off duration for the first cycle of the cadence pattern,
in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-2-on-time - (Optional) Tone-on duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-2-off-time - (Optional) Tone-off duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-3-on-time - (Optional) Tone-on duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-3-off-time - (Optional) Tone-off duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-4-on-time - (Optional) Tone-on duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-4-off-time - (Optional) Tone-off duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
477
© SAMSUNG Electronics Co., Ltd.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ubigate ibg2016

Table of Contents