To define the tone-on and tone-off duration for a call-progress tone, use the
cadence command in call-progress dualtone configuration mode.
Configure>voice class custom-cptone tag dualtone busy cadence {cycle-1-on-
time cycle-1-off-time [cycle-2-on-time cycle-2-off-time] [cycle-3-on-time
cycle-3-off-time] [cycle-4-on-time cycle-4-off-time]}
cycle-1-on-time - Tone-on duration for the first cycle of the cadence pattern,
in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-1-off-time - Tone-off duration for the first cycle of the cadence pattern,
in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-2-on-time - (Optional) Tone-on duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-2-off-time - (Optional) Tone-off duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-3-on-time - (Optional) Tone-on duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-3-off-time - (Optional) Tone-off duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-4-on-time - (Optional) Tone-on duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.
cycle-4-off-time - (Optional) Tone-off duration for the first cycle of the cadence
pattern, in milliseconds(ms). Range is from 0 to 1000. The default is 0.