debug isdn q931-timers
WORD
debug isdn q931Statistics
WORD
© SAMSUNG Electronics Co., Ltd.
Command
Displays q931 timers.
Displays q931 statistics.
Ubigate iBG2016 Configuration Guide/Ed.00
Purpose
v239# show isdn q931-timers bri000
ISDN Layer 3 Timer Values
T303 =
4 Seconds
T304 =
30 Seconds
T305 =
30 Seconds
T308 =
4 Seconds
T310 =
40 Seconds
T313 =
4 Seconds
T316 =
120 Seconds
T319 =
4 Seconds
T322 =
4 Seconds
v239# show isdn q931Statistics
bri000
ISDN Global Configuration
Setup Tx
: 0
Setup Ack Tx : 0
Alert Tx
: 0
Call P Tx
: 0
Conn Tx
: 0
Con Ack Tx
: 0
Prog Tx
: 0
Disc Tx
: 0
Rel Tx
: 0
Rel Cmp Tx
: 0
Stat Tx
: 0
Stat Enq Tx
: 0
Info Tx
: 0
Stat Enq Tx
: 0
Stat Enq Tx
: 0
Setup Rx
: 0
Setup AckRx
: 0
Alert Rx
: 0
Call P Rx
: 0
Conn Rx
: 0
(Continued)