CHAPTER 5. Analog Voice Port
Step
5
8
9
494
Command
signal
{groundstart |
loopstart}
signal {cama {kp-0-
nxx-xxxx-st | kp-0-
npa-nxx-xxxx-st | kp-
2-st | kp-npd-nxx-
xxxx-st}
signal cama-
bellsouteh
locale locale
Purpose
Selects the access signaling type to match that of
the telephony connection you are making.
The keywords are as follows:
loop-start - (default) Uses a closed circuit to indicate
off-hook status; used for residential loops.
ground-start - Uses ground and current detectors;
preferred for PBXs and trunks
kp-0-npa-nxx-xxxx-st 10-digit transmission.
The E.164 number is fully transmitted.
kp-0-nxx-xxxx-st 7-digit automatic number
identification(ANI) transmission. The Numbering
Plan Area(NPA) or area code is implied by the trunk
group and is not transmitted.
kp-2-st Default transmission when the CAMA trunk
cannot get a
corresponding Numbering Plan Digit(NPD) digit in
the look-up table, or when the calling number is
fewer than 10 digits in length.(NPA
digits are not available.)
kp-npd-nxx-xxxx-st 8-digit ANI transmission, where
the NPD is a single multifrequency(MF) digit that is
expanded into the NPA. The NPD table is
preprogrammed in the sending and receiving
equipment(on each end of the MF trunk); for
example: 0= 415, 1=510, 2=650, 3=916 05551234 =
(415) 555-1234, 15551234 = (510) 555-1234, and
so on.
NPD range is from 0 to 3
apply Bell South E911 Case
Selects the two-letter locale for the voice call
progress tones and other locale-specific parameters
to be used on this voice port
The Default is us
ex) locale us