Samsung Ubigate iBG2016 Configuration Manual page 579

Hide thumbs Also See for Ubigate iBG2016:
Table of Contents

Advertisement

Trunk Status Monitoring
This procedure is much like the same as the configuration of E1 trunk.
Details in each following section refer to 'Trunk Status Monitoring'.
Physical Layer Status
Using show voice card all, check all the voice card installed in the system
v239# show voice card all
SLOT CARD TYPE
[DSP] VoIP_M510
[0/0] FXS_4M
[0/1] WTE_2M
[0/2]-
[1/0]-
[1/1]-
[2/0]-
[2/1]-
Using show module configuration, carrier- type and status of trunk in
operation can be checked.
v239# show module configuration t1 0/1/0
T1 0/1/0 is ENABLED
Alarm Hierarchy: TRUE,
Yellow Alarm: DISABLE
Framing:ESF, LineCode:B8ZS, ClockSource: INT, LineMode:CSU,
LBO:0 db
FDL: ANSI Unit Protocol enabled ,ATT Unit Protocol
disabled ,
CsuDsuType: CSU , Loopback Framing(In-band): Overwrite,
CIRCUIT-ID: Not Configured ,CONTACT-INFO: Not Configured ,
DESCRIPTION: Not Configured , LINK NAME: Not Configured ,
Line Status:
RLOS:OFF
TRAI:OFF
Timeslot Map:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
22 23 24
|0 |0 |0 |0 |0 |0 |0 |0 |0 |0 |0 |0 |0 |0 |0 |0 |0 |0 |0 |0
|0 |0 |0 |0 |
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__
|__|__|__|__|
© SAMSUNG Electronics Co., Ltd.
STATUS
NORMAL
NORMAL
NORMAL
-
-
-
-
-
RAIS:OFF
RLOF:OFF
TPtrn:OFF
Loop:OFF
Ubigate iBG2016 Configuration Guide/Ed.00
VS VSLOTNAME
13 VoIP_VSLOT
7 MM_2_VSLOT
6 MM_1_VSLOT
--
--
--
--
--
RRAI:OFF
TAIS:OFF
525

Hide quick links: