Cleaning the centering sensor (Paper feeder unit PF-707/PF-708)
1
Open the front door of the paper feeder
unit.
2
Open the cover [PF4].
3
Clean the centering sensor with a
cleaning pad.
NOTICE
-
Do not use alcohol when you clean the sensor. The
surface of the sensor becomes fuzzy.
NOTICE
-
Do not touch the positioning pin (
cleaning pad since there is grease on the pin.
4
Close the cover [PF4]
5
Close the front door of the paper feeder unit.
) with the
bizhub PRESS C1100/C1085
1-6
1