Set logout Command
The set logout command is used to set the number of minutes until the system
automatically disconnects an idle session.
The syntax for this command is:
set logout <timeout>
timeout
Example:
To set the number of minutes until the system disconnects an idle session
automatically:
P330-N# set logout 20
Sessions will be automatically logged out after 20 minutes of
idle time.
To disable the automatic disconnection of idle sessions:
P330-N# set logout 0
Sessions will not be automatically logged out.
Set timezone Command
Use the set timezone command to assign a timezone name and set the time
difference of your Avaya P330 relative to the Coordinated Universal Time (UTC/
GMT). The minutes parameter can only be set to 30.
The syntax for this command is:
set timezone <zone_name> [-]<hours>[:30]
Example:
set timezone GMT -3:30
Timezone set to 'GMT', offset from UTC is -3:30 hours
Note: If you wish to define a name which includes spaces, you must enclose the
entire name in quotation marks, e.g. "new york".
Avaya P333R-LB User's Guide
Number of minutes (0 to 999) until the system automatically
disconnects an idle session. Setting the value to 0 disables the
automatic disconnection of idle sessions (default is 15 minutes).
Chapter 5
Cajun Campus CLI – Layer 2
95