Use the rmon alarm command to create a new RMON alarm entry.
The syntax for this command is:
rmon alarm <Alarm Number> <variable> <interval> <sampletype>
rising-threshold <rising threshold> <rising event> falling-
threshold <falling threshold> <falling event> <startup alarm>
<owner>
alarm number
variable
interval
sample type
rising threshold
rising event
falling threshold
falling event
startup alarm
owner
Example:
P330-N# rmon alarm 1026 1.3.6.1.2.1.16.1.1.1.5.1026 60 delta
rising-threshold 10000 1054 falling-threshold 10 1054
risingOrFalling amir
alarm 1026 was created successfull
128
This is the alarm index number of this entry (it is advisable to
use the same interface number as your alarm index number.)
This is the MIB variable which will be sampled by the alarm
entry.
The interval between 2 samples
This can be set to either delta (the difference between 2
samples) or an absolute value.
This sets the upper threshold for the alarm entry.
The RMON event entry that will be notified if the upper
threshold is passed.
This sets the lower threshold for the alarm entry.
The RMON event entry that will be notified if the lower
threshold is passed.
The instances in which the alarm will be activated. The
possible parameters are: Rising, Falling, risingOrfalling.
Owner name string