Motorola RFS Series Reference Manual page 118

Wireless lan switches wing system
Hide thumbs Also See for RFS Series:
Table of Contents

Advertisement

4-30 Motorola RF Switch System Reference Guide
MCast Addr 2
NAC Mode
10.Refer to the
messages if something goes wrong in the transaction between the applet and the switch.
11.Click on the
primary and secondary Radius and NAC server. For more information, see
Server Support on page
12.Select the
Syslog
accounting details. To enable syslog, select the
menu. Use this sub screen to provide the Syslog Server IP address and port for the Syslog Server
performing the accounting function.
13.If clustering and the
the
Apply to Cluster
14.Click
OK
to use the changes to the running configuration and close the dialog.
15.Click
Cancel
4.5.1.2 Assigning Multiple VLANs per WLAN
The switch allows the mapping of a WLAN to more than one VLAN. When a MU associates with a WLAN,
it is assigned a VLAN in such a way that users are load balanced across VLANs. The VLAN is assigned from
the pool representative of the WLAN. The switch tracks the number of MUs per VLAN, and assigns the least
used/loaded VLAN to the MU. This number is tracked on a per-WLAN basis.
To assign multiple VLANs to a WLAN:
1. Select
Network
2. Select an existing WLAN from those displayed within the
A WLAN screen displays with the WLAN's existing configuration.
3. Select the
VLAN
WLAN.
By default, all WLANs are initially assigned to VLAN 1.
4. Select the
Dynamic Assignment
WLAN.
5. Select the
Assign Multiple VLAN(s)
Multiple VLAN Mapping screen.
The second address also takes packets (where the first 4 bytes match the first 4
bytes of the mask) and sends them immediately over the air instead of waiting for
the DTIM period. Any multicast/broadcast that does not match this mask will go
out only on DTIM Intervals.
Using Network Access Control (NAC), the switch only grants access to specific
network resources. NAC restricts access to only compliant and validated devices
(printers, phones, PDAs etc.), thereby limiting the risk of emerging security risks.
NAC performs an authorization check for users and MUs without a NAC agent, and
verifies a MU's compliance with the network security policy. The switch supports
only the EAP/802.1x type of NAC. However, the switch can bypass NAC for MU's
without NAC 802.1x support. For the implications of using the include and exclude
with NAC, see
Configuring the NAC Inclusion List on page
NAC Exclusion List on page 4-70
4-48.
Status
field for the current state of the requests made from applet. This field displays error
Radius...
button (when Radius is selected as the accounting mode) to configure an external
4-44.
button (when Syslog is selected as the accounting mode) to view switch syslog
Cluster GUI
feature is enabled the
button to apply the WLAN settings to all members in the cluster.
to close the dialog without committing updates to the running configuration.
>
Wireless LANs
from the main menu tree.
radio button from the Configuration screen to change the VLAN designation for this
checkbox for an user based VLAN assignment with Radius for this
button to map a WLAN to more than one VLAN. This displays the
4-66,
Configuring NAC Server Support on page
and
Configuring External Radius
Syslog
option from the Accounting Mode drop-down
Apply to Cluster
feature will be available. Click
Configuration
tab and click the
Configuring the
Edit
button.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws5100 3.3Rfs6000 3.3Rfs7000 1.3

Table of Contents