Configuring Ethernet Ports

Non-Combo Port Defaults

The following table shows non-combo port default values:
Parameter Description
Interface Line Speed
Duplex Mode
Autonegotiation
Crossover

Combo Ethernet Port Defaults

The following table shows combo Ethernet port default values for OmniSwitch 6800 Series switches only:
Parameter Description
Preferred fiber
Forced fiber
Preferred copper
Forced copper
Flow (pause)
Interface Line Speed
Duplex Mode
Autonegotiation
Crossover
OmniSwitch 6800/6850/9000 Network Configuration Guide
Command
interfaces speed
interfaces duplex
interfaces autoneg
interfaces crossover
Command
interfaces hybrid
preferred-fiber
interfaces hybrid
preferred-copper
interfaces hybrid forced-
fiber
interfaces hybrid forced-
copper
interfaces hybrid speed
interfaces hybrid speed
interfaces hybrid duplex
interfaces hybrid
autoneg
interfaces hybrid
crossover
March 2008
Non-Combo Port Defaults
Default Value/Comments
Auto (copper ports)
100 Mbps (fiber ports)
1 Gbps (GNI ports)
10 Gbps (XNI ports)
Auto (copper ports)/Full (fiber,
GNI and XNI ports)
Enable for all copper ports;
Disable for all fiber ports
Auto for all copper ports;
MDI for all fiber ports (not config-
urable on fiber ports)
Default Value/Comments
Preferred fiber
Disabled
Auto
Auto
Enable
Auto for all copper ports