Configuring Global QoS Parameters
Note. If you change the number of log lines, the QoS log may be completely cleared. To change the log
lines without clearing the log, set the log lines in the boot.cfg file; the log will be set to the specified
number of lines at the next reboot.

Log Detail Level

To change the level of detail in the QoS log, use the
amount of detail that will be given in the QoS log. The qos log level command is associated with the qos
debug command, which determines what kind of information will be included in the log.
The default log level is 6. The range of values is 1 (lowest level of detail) to 9 (highest level of detail). For
example:
-> qos log level 7
The log level is changed immediately but the setting is not saved in flash. To activate the change, enter the
qos apply command. For more information about the qos apply command, see
tion" on page
30-54.
Note. A high log level value will impact the performance of the switch.

Forwarding Log Events

NMS applications may query the switch for logged QoS events. Use the
make QoS log events available to these applications in real time. For example:
-> qos forward log
To disable log forwarding, enter the following command:
-> qos no forward log
To activate the change, enter the qos apply command. For more information about the qos apply
command, see
"Applying the Configuration" on page
If event forwarding is disabled, NMS applications will still be able to query the QoS software for events,
but the events will not be sent in real time.

Forwarding Log Events to the Console

QoS log messages may be sent to the switch logging utility, which is an event logging application avail-
able on the OmniSwitch. The configuration of the switch logging utility then determines if QoS messages
are sent to a log file in the switch's flash file system, displayed on the switch console, and/or sent to a
remote syslog server.
To send log events to the switch logging utility, enter the following command:
-> qos log console
To disable immediate forwarding of events to switch logging, enter the following command:
-> qos no log console
To activate the change, enter the qos apply command. For more information about the qos apply
command, see
"Applying the Configuration" on page
page 30-20
qos log level
30-54.
30-54.
OmniSwitch 6800/6850/9000 Network Configuration Guide
Configuring QoS
command. The log level determines the
"Applying the Configura-
qos forward log
command to
March 2008

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch 6850 seriesOmniswitch 9000 series

Table of Contents