Configuring A Probe Send; Configuring A Probe Expect - Alcatel-Lucent OmniSwitch 6800 Series Network Configuration Manual

Hide thumbs Also See for OmniSwitch 6800 Series:
Table of Contents

Advertisement

Configuring SLB Probes

Configuring a Probe Send

To configure an ASCII string sent to a server to invoke a response from it and to verify its health use the
ip slb probe send
command by entering ip slb probe followed by the user-configured probe name, the
valid probe type (udp or tcp), send, and the user-specified ASCII string.
For example, to set the TCP/UDP port for an TCP SLB probe called "server_probe1" to "test", enter:
-> ip slb probe server_probe1 tcp send test

Configuring a Probe Expect

To configure an ASCII string used to compare a response from a server to verify the health of the server
use the
ip slb probe expect
name, the valid probe type (http, https, udp, or tcp), expect, and the user-specified ASCII string.
For example, to set the TCP/UDP port for an HTTP SLB probe called "server_probe1" to "test", enter:
-> ip slb probe server_probe1 http expect test
page 34-34
command by entering ip slb probe followed by the user-configured probe
OmniSwitch 6800/6850/9000 Network Configuration Guide
Configuring Server Load Balancing
March 2008