Associating A Probe With A Server; Modifying Slb Probes; Modifying The Probe Timeout; Modifying The Probe Period - Alcatel-Lucent OmniSwitch 6800 Series Network Configuration Manual

Hide thumbs Also See for OmniSwitch 6800 Series:
Table of Contents

Advertisement

Configuring SLB Probes

Associating a Probe with a Server

To associate an existing SLB probe with a server use the
entering ip slb server ip followed by IP address of the server, cluster, the user-configured cluster name,
probe, and the user-configured probe name.
For example, to associate a probe called "server_probe1" with a server with an IP address of
10.255.11.127 that belongs to a cluster called "WorldWideWeb", enter:
-> ip slb server ip 10.255.11.127 cluster WorldWideWeb probe server_probe1

Modifying SLB Probes

The following subsections describe how to modify existing SLB probes.

Modifying the Probe Timeout

By default, the timeout used to wait for SLB probe answers is 3000 seconds. To modify this value from 1
to 3600000 seconds use the
user-configured probe name, the probe type, timeout, and the user-specified timeout value.
Note. See
"Creating SLB Probes" on page 34-31
For example, to set the timeout for an HTTP SLB probe called "server_probe1" to 12000 seconds, enter:
-> ip slb probe server_probe1 http timeout 12000

Modifying the Probe Period

By default, the SLB probe period to check the health of servers is 60 seconds. To modify this value from 0
to 3600 seconds use the
configured probe name, the probe type, period, and the user-specified period value.
Note. See
"Creating SLB Probes" on page 34-31
For example, to set the period for an HTTP SLB probe called "server_probe1" to 120 seconds, enter:
-> ip slb probe server_probe1 http period 120

Modifying the Probe TCP/UDP Port

By default, the TCP/UDP port the SLB probe should be sent on is 0. To modify this value from 0 to 65535
use the
ip slb probe port
the probe type, port, and the user-specified port number.
Note. See
"Creating SLB Probes" on page 34-31
For example, to set the TCP/UDP port for an HTTP SLB probe called "server_probe1" to 200 enter:
-> ip slb probe server_probe1 http port 200
page 34-32
ip slb probe timeout
ip slb probe period
command by entering ip slb probe followed by the user-
command by entering ip slb probe followed by the user-configured probe name,
OmniSwitch 6800/6850/9000 Network Configuration Guide
Configuring Server Load Balancing
ip slb server ip cluster probe
command by entering ip slb probe followed by the
for a list of valid probe types.
for a list of valid probe types.
for a list of valid probe types.
command by
March 2008

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch 6850 seriesOmniswitch 9000 series

Table of Contents