Configuring Ethernet Ports
3
Verify that combo ports 1/47 and 1/48 are set to the default setting of preferred fiber (which will make
the SFP connectors 1/47 and 1/48 the primary connections while copper combo ports 1/47 and 1/48 will
only become active if the equivalent SFP connectors go down) with the
as shown below:
-> show interfaces 1/45-48 status
Slot/ AutoNego
Port
-----+--------+------+------+------+--------+------+------+------
1/45
Enable
1/45
Enable
1/46
Enable
1/46
Enable
1/47
Enable
1/47
Enable
1/48
Enable
1/48
Enable
FF - ForcedFiber PF - PreferredFiber
FC - ForcedCopper PC - PreferredCopper C - Copper
In the output above combo ports 1/47 and 1/48 are set to preferred fiber. (To configure combo ports as
preferred fiber use the
OmniSwitch 6800/6850/9000 Network Configuration Guide
DETECTED
Speed Duplex Hybrid
(Mbps)
Type
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
interfaces hybrid preferred-fiber
show interfaces status
CONFIGURED
Speed
Duplex Hybrid
(Mbps)
Mode
100
Auto
FC
1000
Full
FC
100
Auto
FC
1000
Full
FC
1000
Full
PF
100
Auto
PF
1000
Full
PF
100
Auto
PF
F - Fiber
command.)
March 2008
Combo Port Application Example
command
Trap
LinkUpDown
-
-
-
-
-
-
-
-
page 37-25