Operations In The Channel Display Screen - Roland M-480 Owner's Manual

Live mixing console
Hide thumbs Also See for M-480:
Table of Contents

Advertisement

AUX, MTX, MAIN operations

Operations in the CHANNEL DISPLAY screen

The principal parameters of the
CHANNEL DISPLAY screen
fig.ScrChMainGuide.eps
4
1
2
3
11
1
ATT (Attenuator)
fig.ScrMtxAttGuide.eps
1
2
OL (Overload) indicator
1
This will light red when the output of the attenuator exceeds
the OVER Lev setting specified in the METER SETUP popup
(p. 96).
ATT knob
2
This adjusts the channel's input level in a range of -48 dB–0
dB (6 dB steps).
Normally, you should leave the attenuator set at 0 dB. It is
convenient to use the attenuator in situations like the
following:
• When the input of an AUX, MTX, MAIN is overloaded
and must be lowered
60
AUX, MTX, and MAIN
can be operated in the CHANNEL DISPLAY screen.
5
8
9
10
12
7
2
Limiter
fig.ScrChLim.eps
4
1
5
2
3
LIM button
1
This turns the limiter on/off.
IN meter
2
This indicates the input level of the limiter. For stereo-linked
channels, two meters (L and R) are shown.
GR meter
3
This indicates the amount of gain reduction produced by the
limiter.
OL (Overload) indicator
4
This will light red when the output of the limiter exceeds the
OVER Lev setting specified in the
96).
THRE knob
5
This adjusts the limiter's threshold level in a range of -40.0
dB–0.0 dB.
6
METER
SETUP popup (p.

Advertisement