Fader Calibration - Roland M-480 Owner's Manual

Live mixing console
Hide thumbs Also See for M-480:
Table of Contents

Advertisement

Fader calibration

If the fader positions are no longer aligned with the index
markings of the top panel, you can use the Fader Calibration
function to correct the misalignment.
1.
In the SETUP section, hold down [SYSTEM] and turn the
power on.
fig.SystemConfig.eps
The
M-480
will start up in SYSTEM CONFIG MODE, and the
SYSTEM CONFIG screen will appear.
2.
Press [F3 (Fader Calibrate)].
fig.FaderCalibration.eps
1
2
The FADER CALIBRATION popup will appear.
1
Fader select buttons
Use these buttons to select the fader that you want to
calibrate.
2
Fader indication
These indicate the internal fader positions and volume (dB).
The function buttons have the following operations:
[F1 (Set -Inf dB Position)] Sets the current top panel position of the
selected fader to -Inf dB.
[F2 (Set -20 dB Position)] Sets the current top panel position of the
selected fader to -20 dB.
[F3 (Set 0 dB Position)]
Sets the current top panel position of the
selected fader to 0 dB.
[F4 (Set 10 dB Position)]
Sets the current top panel position of the
selected fader to 10 dB.
[F5 (Init Position)]
Initializes the calibration setting of the
selected fader.
[F7 (SELECT All Fader)]
Adds or clears the check mark for all fader
select buttons.
[F8 (CLOSE)]
Closes the FADER CALIBRATION popup.
Other settings and functions
3.
Add a check mark to the fader select button of the fader
you want to adjust.
You can also use the top panel [SEL] buttons to add or clear the
check mark for the fader select buttons.
4.
Move the selected fader to the position you want to
specify.
You can specify the following four points:
• 10 dB (all the way up)
• 0 dB
• -20 dB
• -Inf dB (all the way down)
We recommend that you adjust all of the above four points for
each fader that has drifted out of calibration.
5.
Press the function button that corresponds to the
location at which you set the fader.
Position
10 dB (all the way up)
0 dB
-20 dB
-Inf dB (all the way down)
fig.FaderCalibrationConfirm.eps
A message will ask you to confirm the operation.
6.
Press [F8 (SET)].
The fader position will be specified for the selected fader.
If the relationship of -Inf dB < -20 dB < 0 dB < 10 dB is not
maintained, the setting will be ignored when you press [F8
(SET)].
7.
Press [F8 (CLOSE)].
The FADER CALIBRATION popup will close.
8.
Turn off the power.
Function button
[F4 (Set 10dB Position)]
[F3 (Set 0dB Position)]
[F2 (Set -20dB Position)]
[F1 (Set -Inf dB Position)]