Setting the Date and Time

1.
At the HOME screen, tap <DATE & TIME AREA>.
The DATE & TIME window appears.
2.
Set the date and time, then tap <SET>.
The settings for the date and time are applied.

Factory Reset

This initializes the M-5000, returning it to its factory-default state.
NOTE
Performing initialization causes all data to be lost.
Data that is needed can be saved to a USB flash drive.
0"Backing Up All Data in the M-5000" (p. 59)
0"Restoring All Data in the M-5000" (p. 60)
1.
Go to the Display section on the top panel, and while
holding down the [MENU] button and [VIEW] button, turn
on the power to the M-5000.
2.
Tap <FACTORY INITIALIZE>.
A popup prompting you to confirm the initialization operation is
displayed.
3.
Tap <INITIALIZE>.
Initialization starts.
NOTE
Never turn off the power to the M-5000 before initialization
finishes.
4.
When "Factory Initialize completed." appears, turn off the
power.

Fader Calibration

If the fader positions are no longer aligned with the index markings
of the top panel, carry out fader calibration to adjust.
1.
Press the [MENU] button.
2.
AT the MENU window, tap <SYSTEM>, then tap <FADER
CALIBRATION>.
The FADER CALIBRATION window appears.
3.
Tap an item from <-INF> to <+10dB>.
This moves to the location where all faders are supported.
4.
Adjust the fader that is not aligned with the index
markings on the top panel.
The <UPDATE> appears.
5.
Tap <UPDATE>.
The fader position is adjusted to the specified location.