10.6.3.2
show line vty
This command displays telnet settings.
Syntax
show line vty
Default Setting
None
Command Mode
Privileged Exec
Display Message
Remote Connection Login Timeout (minutes): This object indicates the number of minutes a
remote connection session is allowed to remain inactive before being logged off. A zero means there
will be no timeout. May be specified as a number from 0 to 160. The factory default is 5.
Maximum Number of Remote Connection Sessions: This object indicates the number of
simultaneous remote connection sessions allowed. The factory default is 5.
Allow New Telnet Sessions: Indicates that new telnet sessions will not be allowed when set to no.
The factory default value is yes.
Password Threshold: When the logon attempt threshold is reached on the console port, the system
interface becomes silent for a specified amount of time before allowing the next logon attempt. (Use
the silent time command to set this interval.) When this threshold is reached for Telnet, the Telnet
logon interface closes.
10.6.3.3
line vty
This command is used to enter vty (Telnet) configuration mode.
Syntax
line vty
Default Setting
None
Command Mode
Global Config
2011 Fujitsu Technology Solutions
©