Fujitsu PRIMERGY BX900 User Manual page 274

Blade server systems ethernet connection blade module sb6 / sb11a / sb11 switch version
Hide thumbs Also See for PRIMERGY BX900:
Table of Contents

Advertisement

9.4.1.2
Port Config
Figure : Port Access Control Port Config
Selection Criteria
Port - Selects the port to be configured. When the selection is changed, a screen refresh will occur
causing all fields to be updated for the newly selected port. All physical interfaces are valid.
Control Mode - This selector lists the options for control mode. The control mode is only set if the
link status of the port is link up. The options are:
force unauthorized: The authenticator port access entity (PAE) unconditionally sets the
controlled port to unauthorized
force authorized: The authenticator PAE unconditionally sets the controlled port to
authorized.
auto: The authenticator PAE sets the controlled port mode to reflect the outcome of the
authentication exchanges between the supplicant, authenticator, and the authentication
server.
Reauthentication Enabled - This select field allows the user to enable or disable reauthentication of
the supplicant for the specified port. The selectable values are 'true' and 'false'. If the value is 'true'
reauthentication will occur. Otherwise, reauthentication will not be allowed. The default value is false.
Changing the selection will not change the configuration until the Apply button is pressed.
Configurable Data
Quiet Period - This input field allows the user to configure the quiet period for the selected port. This
command sets the value, in seconds, of the timer used by the authenticator state machine on this
port to define periods of time in which it will not attempt to acquire a supplicant. The quiet period is
the period for which the authenticator does not attempt to acquire a supplicant after a failed
authentication exchange with the supplicant. The quiet period must be a number in the range of 0
and 65535. A quiet period value of 0 means that the authenticator state machine will never acquire a
supplicant. The default value is 60. Changing the value will not change the configuration until the
Apply button is pressed.
2011 Fujitsu Technology Solutions
©
272

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy bx400

Table of Contents