General LED (SB6 / SB11a)
There is one Ethernet Connection Blade Module system LED with dual functions, controlled by MMB for
error status reporting and blade identification. Different flashing frequencies are used to indicate the
different functions. There are two functions, identification and error reporting, with identification having a
higher priority than error reporting.
LED
Color
ID
Blue
Off
Green
Status
Orange
Blinking
Off
General LED (SB11)
There is one Ethernet Connection Blade Module system LED with dual functions, controlled by MMB for
error status reporting and blade identification. Different flashing frequencies are used to indicate the
different functions. There are two functions, identification and error reporting, with identification having a
higher priority than error reporting.
LED
Color
ID
Blue
Off
Green
Status
Orange
Blinking
Off
Green
S1
Green Blinking
Off
Green
S2
Green Blinking
Off
Yellow
Yellow Blinking
Stack
Green
Green Blinking
Off
Function
Identify Connection Blade
normal
Power On
Connection Blade Failure
Power Off
Function
Identify Connection Blade
normal
Power On
Connection Blade Failure
Power Off
Internal Stacking Port1 Link
Internal Stacking Port1 Activity
No Stacking Port1 Link
External Stacking Port2 Link
External Stacking Port2 Activity
No Stacking Port2 Link
Connection Blade is Stack Master
Connection Blade is not able to perform Master
Function
Connection Blade is Stack Slave
Master Election Process active
Connection Blade is not in a Stack
2011 Fujitsu Technology Solutions
©