Fujitsu PRIMERGY BX924 S3 Operating Manual

Server blade
Hide thumbs Also See for PRIMERGY BX924 S3:
Table of Contents

Advertisement

Operating Manual - English
PRIMERGY BX924 S3

Server Blade

Operating Manual
April 2012

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu PRIMERGY BX924 S3

  • Page 1: Server Blade

    Operating Manual - English PRIMERGY BX924 S3 Server Blade Operating Manual April 2012...
  • Page 2: Copyright And Trademarks

    – The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. – No part of this manual may be reproduced in any without the prior written permission of Fujitsu.
  • Page 3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product.
  • Page 4 Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning.
  • Page 5 Only for the Japanese market: Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – CSS (Customer Self Service) Operating Manual BX924 S3...
  • Page 6 Operating Manual BX924 S3...
  • Page 7: Table Of Contents

    Contents Introduction ......9 Concept and target groups for this manual ..9 Documentation overview .
  • Page 8 Contents Starting up and operation ....47 Control and display elements ....47 Switching the Server Blade on and off .
  • Page 9: Introduction

    This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the information you need to put your PRIMERGY BX924 S3 server blade into operation. To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system.
  • Page 10: Documentation Overview

    Introduction Documentation overview More information on your PRIMERGY BX924 S3 server blade can be found in the following documents: – "Quick Start Software - Quick Installation Guide" DVD booklet (only included as a printed copy with the ServerView Suite) – "Safety Notes and Regulations" manual "...
  • Page 11: Notational Conventions

    Introduction Further sources of information: – ServerView Suite Glossary on the ServerView Suite DVD 2 – Manual for the monitor – Documentation for the boards and drives – Operating system documentation – Information files in your operating system Notational conventions The following notational conventions are used in this manual: Text in italics indicates commands or menu items.
  • Page 12 Introduction Operating Manual BX924 S3...
  • Page 13: Functional Overview

    Functional overview The PRIMERGY BX924 S3 server blade is an Intel-based dual-socket server blade. It is ideal for use in data centers belonging to enterprises or Internet service providers, and makes an excellent large application server, terminal server for compute-intensive applications or DBMS server.
  • Page 14 (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system (for more information, refer to the “D3143 BIOS Setup Utility for PRIMERGY BX924 S3 Reference Manual"). CAUTION! – When using the TPM, note the program descriptions provided by the third party manufacturers.
  • Page 15 Functional overview SSD drives Two SSD drives (Solid State Disk drives) can be installed in the server blade. The connection to the onboard controller is established through ports on the system board. Onboard SAS/SATA controller A SAS/SATA controller is integrated on the system board; up to two SAS or SATA drives can be connected to the controller.
  • Page 16 Functional overview – 10 Gbit/s CNA mezzanine card with 2 ports – 40-Gbit/s Infiniband mezzanine card with 2 ports – 56-Gbit/s Infiniband mezzanine card with 2 ports If a server blade is configured with one or two mezzanine cards, this does not exclude other configurations for any of the other server blades in a system unit.
  • Page 17 ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the event of an error and automatically "hides" the defective system components. The PDA (Prefailure Detection and Analyzing) technology from Fujitsu Technology Solutions analyzes and monitors all components that are critical for system reliability.
  • Page 18 Server management is implemented using the ServerView Operations Manager supplied and the PDA (Prefailure Detection and Analysis) technology from Fujitsu. PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken.
  • Page 19 Functional overview ServerView Installation Manager You can configure the PRIMERGY server quickly and precisely with the ServerView Installation Manager software provided. User-guided menus are available for installing the server operating system (for further details see section "Configuring the Server Blade" on page 52).
  • Page 20: Server Specification

    Functional overview Server specification This section explains the specifications for the server blade. The specifications for this server blade are liable to be updated without any notice. Please be forewarned. System Board System board type D3143 ® Chipset Intel C600 Processor ®...
  • Page 21 Functional overview Onboard or integrated controllers RAID Controller Modular RAID 5/6 controller with "MegaRAID functionality" (SAS MegaRAID) for SAS1.0 and SAS2.0. RAID levels 0, 1, 10, 1E, 5, 50, 6 and 60 are supported for internal hard disk drive configurations. SAS/SATA Controller A 6-port SAS/SATA controller is integrated on the system board;...
  • Page 22: O Indicator: Fabric

    Functional overview Operating Panel Operating buttons On/off button ID button Status LEDs Power indicator (orange / yellow / green) ID indicator (blue) Global error indicator (orange) CSS indicator (yellow) I/O indicator: fabric 1 (green) I/O indicator: fabric 2 (green) I/O indicator: fabric 3/4 (green) Dimensions / Weight Width 45 mm...
  • Page 23 Functional overview Electrical values Energy consumption 370 W (fully equipped) 471 W (fully equipped) 2x 95W CPU 2x 130W CPU Heat dissipation 1,332 kJ/h 1,696 kJ/h Compliance with regulations and standards Product safety and ergonomics International IEC 60950-1 2ed. Europe Safety EN 60950-1 2ed.
  • Page 24 Functional overview Certification Product safety approved with the system unit Global Germany GS, CE USA/Canada /CSA Japan VCCI China/Taiwan BSMI CAUTION! When using 130W CPU´s or 95W CPU´s plus SSD the system performance may be reduced if operating with a fan fault or above 30°C. Operating Manual BX924 S3...
  • Page 25: Installation Steps, Overview

    Installation steps, overview This chapter contains an overview of the steps necessary to install your Server Blade. The cross-references take you to the sections containing more detailed information on the relevant installation step: Ê First read the chapter "Important Information" on page 27, particularly the section "Safety instructions".
  • Page 26 Installation steps, overview – Local installation with or without ServerView Installation Manager Local installation is the least convenient method. It is only recommended if the requirements for remote installation and cloning are not met. If you want to install an operating system that is not supported by ServerView Installation Manager, you can of course install it directly without ServerView Installation Manager.
  • Page 27: Important Information

    Important Information This chapter provides safety instructions which you must observe when handling your server. Safety instructions The following safety instructions are also provided in the manual "Safety Notes and Regulations" or " 安全上のご注意 ". This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team.
  • Page 28 Important Information Before starting up CAUTION! During installation and before operating the device, observe the ● instructions on environmental conditions for your device (see "Server specification" on page 20). If the server has been moved from a cold environment, condensation ●...
  • Page 29 Important Information CAUTION! In emergencies (e.g. damaged casing, control elements or power ● cable, penetration of liquids or foreign bodies), switch off the device immediately, unplug it from the grounded power outlets, and contact your customer service center. Proper operation of the device (in accordance with IEC 60950- ●...
  • Page 30 ● concerning special waste. Replace the lithium battery on the system board in accordance with ● the instructions in the "PRIMERGY BX924 S3 Server Blade Upgrade and Maintenance Manual". All batteries containing pollutants are marked with a symbol (a ●...
  • Page 31 Important Information Under certain circumstances, sharp CD/DVD/BD fragments can pierce the cover of the optical drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck). High humidity and airborne dust levels are to be avoided. Electric ●...
  • Page 32 Important Information To avoid dust, damage, and deformation, keep the CD/DVD/BD in its ● case whenever it is not in use. Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to ● prolonged direct sunlight or near heating appliances are to be avoided.
  • Page 33: Ce Conformity

    Important Information Switch off the system and remove the power plugs from the power outlets ● before installing or removing components with ESDs. You must always discharge static build-up (e.g. by touching a grounded ● object) before working with such components. Any devices or tools that are used must be free of electrostatic charge.
  • Page 34: Fcc Class A Device

    Important Information FCC class A device Warning! This is class A product, which may cause radio interference in a domestic environment. If this is the case, the user may be required to take adequate measures. Transporting the Server Blade CAUTION! Only transport the server blade in its original packaging or in suitable packaging which protects it from knocks and jolts.
  • Page 35: Environmental Protection

    Important Information Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
  • Page 36 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 37: Hardware Installation

    Hardware installation CAUTION! Follow the safety instructions in the chapter "Important Information" ● on page Do not expose the server to extreme environmental conditions (see ● "Ambient conditions" on page 22). Protect the server from dust, humidity and heat. Make sure that the server is acclimatized for the time indicated in this ●...
  • Page 38: Unpacking The Server Blade

    Hardware installation Unpacking the server blade CAUTION! Follow the safety instructions in chapter "Important Information" on page Do not unpack the server blade until it is at its installation location. Ê Transport the server blade to the place where you want to set it up. Ê...
  • Page 39 Hardware installation To add a server blade, you must first remove a dummy module from the relevant slot. Figure 2: Removing the Server Blade dummy module Ê Pull up the handle of the dummy module (arrow) to unlock it. Ê Pull the dummy module out of the slot. CAUTION! Keep the dummy module for future use.
  • Page 40 Hardware installation Installing the Server Blade CAUTION! Follow the safety instructions and information in section "Modules with Electrostatic-Sensitive Devices" on page Figure 3: Installing the Server Blade Ê Open the release lever. Ê Push the server blade as far as possible into the slot. Operating Manual BX924 S3...
  • Page 41 Hardware installation Figure 4: Locking the Server Blade Ê Pull the release lever up until it engages. Removal is carried out in reverse order. CAUTION! If you remove a server blade and do not replace it with a new one, you must install a dummy module to comply with the regulations regarding electromagnetic compatibility and to ensure sufficient cooling of the system components.
  • Page 42: Connecting Devices

    Hardware installation Connecting devices All connections that are required to operate the server blade are made via the midplane of the system unit. When the server blade is installed, midplane contacts automatically establish connections to the infrastructure modules on the rear of the system unit: –...
  • Page 43: Instructions For Connecting/Disconnecting Cables

    Hardware installation Instructions for connecting/disconnecting cables CAUTION! Be sure to read the documentation for the peripheral devices before connecting them. Do not connect or disconnect data cables during a thunderstorm. When removing a cable, always hold it by the plug. Never unplug a cable by pulling at the cable itself.
  • Page 44 Hardware installation Using the Y-cable When engaging between the Y-cable connector and the server blade connector is strong, and the Y cable is detached as it is, the Y-cable connector might be damaged. Therefore, please remove the Y-cable as follows. Procedure for detaching the Y-cable While strongly pushing the hook of the Y-cable connector (Server Blade side : 2 points),...
  • Page 45 Hardware installation Figure 7: BX400 S1 system unit (floorstand version) Important You may find it difficult to remove the Y-cable because the load hangs in the ● join with the Y-cable connector. Therefore make sure it is straight when you remove it. Do not leave a Y-cable connected.
  • Page 46 Hardware installation Operating Manual BX924 S3...
  • Page 47: Starting Up And Operation

    Starting up and operation CAUTION! Follow the safety instructions in the chapter "Important Information" on page Control and display elements Figure 8: Control and display elements ID card CSS indicator I/O indicator: fabric 3/4 Global Error indicator I/O indicator: fabric 2 ID button with ID indicator I/O indicator: fabric 1 On/Off button with power indicator...
  • Page 48 Starting up and operation Control elements On/Off button When the server blade is switched off, it can be switched on again by pressing the On/Off button. When the server blade is operating, pressing the On/Off button will switch off the server blade . CAUTION! Risk of loss of data! The On/Off button does not disconnect the server blade from...
  • Page 49: Global Error Indicator

    Starting up and operation Global Error indicator (orange) – Lights up orange if a prefailure event has been detected that requires (precautionary) service intervention. – Flashes orange if an error was detected that requires service intervention. – Does not light up if there is no critical event. If the event is still acute after a power failure, the indicator is activated after the restart.
  • Page 50 Starting up and operation I/O indicators* (green) – Lights up to indicate a network connection. – Flashes to indicate an active network connection. – Does not light up if there is no network connection. * The three I/O fabrics of the server blade are: –...
  • Page 51: Switching The Server Blade On And Off

    Starting up and operation Switching the Server Blade on and off CAUTION! If you switch the server blade on and flickering stripes appear on the connected monitor, switch the server blade off again immediately (see chapter "Troubleshooting and tips" on page 61).
  • Page 52: Configuring The Server Blade

    Starting up and operation Configuring the Server Blade This section contains information about configuring the server blade and installing the operating system. The operating system can be installed in various ways: – Local installation with or without the ServerView Installation Manager You can find information on local installation in the following sections.
  • Page 53: Preparation For Remote Installation To Use Advanced Video Redirection

    Starting up and operation 6.3.2 Preparation for remote installation to use Advanced Video Redirection Advanced Video Redirection (AVR) can be used with the iRMC S3 Web user interface and the Management Blade Web user interface. This section describes how to prepare for using the Web user interface for management blades.
  • Page 54 Starting up and operation For the PRIMERGY BX400 system unit, log onto the blade server and then switch to the Web user interface (Advanced) via the "Experience" drop-down list in the top right. c) iRMC S3 1. Start your Web browser on the remote control terminal and log on to Management Blade Web user interface.
  • Page 55: Configuring The Onboard Sas/Sata Controller

    The SAS functionality needs to be enabled separately by using a ROM1 SCU Key. Descriptions of operating systems not covered in the controller manual are provided in the corresponding readme under: http://www.fujitsu.com/global/services/computing/server/ia/driver/index.html (for the EMEA market). http://jp.fujitsu.com/platform/server/primergy/downloads/ (for the Japanese market).
  • Page 56: Configuring The Server And Installing The Operating System With The Serverview Installation Manager

    This configuration is detected automatically. Descriptions of operating systems not covered in the RAID controller manual are provided in the corresponding readme files under http://www.fujitsu.com/global/services/computing/server/ia/driver/index.html. To find out how to operate the ServerView Installation Manager and for further information, refer to the associated manual.
  • Page 57: Configuring The Server And Installing The Operating System Without Serverview Installation Manager

    Starting up and operation 6.3.6 Configuring the server and installing the operating system without ServerView Installation Manager Configuring the onboard SAS/SATA controller Configure the controller as described in section "Configuring the onboard SAS/SATA controller" on page Configuring the onboard CNA controller Configure the controller as described in section "Configuring the onboard CNA controller"...
  • Page 58: Cleaning The Server Blade

    Starting up and operation Cleaning the Server Blade CAUTION! Switch off the server blade and remove it from the system unit (see page 40). Do not clean any interior parts of the server blade yourself; leave this job to a service technician. Do not use abrasive powder or detergents which dissolve plastic to clean the housing exterior.
  • Page 59: Property And Data Protection

    Property and data protection The lockable rack door protects the server against unauthorized access. To protect the system and data internally against unauthorized access, you can activate the security functions of the BIOS Setup. BIOS Setup security functions The Security menu in the BIOS Setup provides you with various options for protecting your data from unauthorized access.
  • Page 60 Property and data protection Operating Manual BX924 S3...
  • Page 61: Troubleshooting And Tips

    Troubleshooting and tips CAUTION! Follow the safety instructions in the "Safety notes and regulations" manual or " 安全上のご注意 " and in chapter "Important Information" on page If a fault occurs, attempt to resolve it using the measures described: – in this chapter, –...
  • Page 62: Flickering Stripes On Monitor Screen

    Troubleshooting and tips Ê Deactivate screen saver. Enter the appropriate password. Brightness control is set to dark Ê Set the brightness control on the monitor to light. For detailed information, refer to the operating manual supplied with your monitor. Power cable or monitor cable not connected Ê...
  • Page 63: No Screen Display Or Display Drifts

    If the date and time are still wrong after the server has been switched off and back on again, replace the lithium battery (for a description refer to the PRIMERGY BX924 S3 Server Blade Upgrade and Maintenance Manual) or contact our customer service team.
  • Page 64: Hard Disk Drive Error Messages At System Boot

    Troubleshooting and tips Power budget limit value exceeded Ê Check whether the power budget limit value set in the management blade has been exceeded. You may need to install an additional power supply unit. Hard disk drive error messages at system boot Various hard disk drive error messages may appear when the system is rebooted.