Fujitsu PRIMERGY BX900 User Manual page 252

Blade server systems ethernet connection blade module sb6 / sb11a / sb11 switch version
Hide thumbs Also See for PRIMERGY BX900:
Table of Contents

Advertisement

9.3.19.2
Config
The purpose of the pin group configuration is to create pin groups, and to modify the existing pin groups.
Both the internal ports and external ports could be defined to be the member of the pin groups.
Figure : Pin Group Config
Selection Criteria
Auto Uplink VLAN Synchronization Mode –Selects the Auto VLAN Sync mode for enable or
disable.
Repinning Timer – Specify the delay between the link up of the link and repining. The default
repining timer is 10 seconds.
Group Name - Use this pull-down menu to select one of the existing groups.
Participation - Use this field to specify whether a interface will participate in this pin group. The
factory default is 'Exclude'. The possible values are:
Include - This interface is the member of the pin group.
Exclude - This interface is not the member of the pin group.
Configurable Data
Group Name - Input the group name to create a new pin group.
Non-Configurable Data
Unit/Slot/Port - The interface.
Type - The interface type. Type should be Internal, External or Port Channel.
Status - Indicates the current value of the participation parameter for the interface.
Command Buttons
Apply - Update the Switch with the values on this screen. If you want the Switch to retain the new
values across a power cycle, you must perform a save.
Delete - Delete the pin group. You are not allowed to delete the "default" pin group.
2011 Fujitsu Technology Solutions
©