10.4.6.2.2 ip igmp snooping groupmembershipinterval
This command sets the IGMP Group Membership Interval time on the system. The Group Membership
Interval time is the amount of time in seconds that a switch will wait for a report from a particular group
on a particular interface before deleting the interface from the entry. This value must be greater than the
IGMP Maximum Response time value. The range is 2 to 3600 seconds.
Syntax
ip igmp snooping groupmembershipinterval <2-3600>
no ip igmp snooping groupmembershipinterval
<2-3600> - interval time (Range: 2 - 3600) in seconds.
no - This command sets the IGMP Group Membership Interval time on the system to 260 seconds.
Default Setting
260 seconds
Command Mode
Global Config, Interface Config
10.4.6.2.3 ip igmp snooping interfacemode
This command enables IGMP Snooping on a selected interface. If an interface which has IGMP
Snooping enabled is enabled for routing or is enlisted as a member of a port-channel (LAG), IGMP
Snooping functionality will be disabled on that interface. IGMP Snooping functionality will subsequently
be re-enabled if routing is disabled or port-channel (LAG) membership is removed from an interface that
has IGMP Snooping enabled.
Syntax
ip igmp snooping interfacemode
no ip igmp snooping interfacemode
no - This command disables IGMP Snooping on a selected interface.
Default Setting
Disabled
Command Mode
Interface Config