Fujitsu PRIMERGY BX900 User Manual page 258

Blade server systems ethernet connection blade module sb6 / sb11a / sb11 switch version
Hide thumbs Also See for PRIMERGY BX900:
Table of Contents

Advertisement

9.3.20.3
MST
Figure : Spanning Tree MST Config
Selection Criteria
MST ID - Create a new MST which you wish to configure or configure already existing MSTs.
Configurable Data
MST ID - This is only visible when the select option of the MST ID select box is selected. The ID of
the MST being created. Valid values for this are between 1 and 4094.
Priority - The bridge priority for the MST instance selected. The bridge priority is set in multiples of
4096. For example if the priority is attempted to be set to any value between 0 and 4095, it will be set
to 0. If it is tried to be set to any value between 4096 and (2*4096-1) it will be set to 4096 and so on.
VLAN ID - This gives a list box of all VLANs on the switch. The VLANs associated with the MST
instance which is selected are highlighted on the list. These can be selected or unselected for
re-configuring the association of VLANs to MST instances.
Non-Configurable Data
Bridge identifier - The bridge identifier for the selected MST instance. It is made up using the bridge
priority and the base MAC address of the bridge.
Time since topology change - The time n seconds since the topology of the selected MST instance
last changed.
Topology change count - Number of times topology has changed for the selected MST instance.
Topology change - The value of the topology change parameter for the switch indicating if a
topology change is in progress on any port assigned to the selected MST instance. It takes a value if
True or False.
Designated root - The bridge identifier of the root bridge. It is made up from the bridge priority and
the base MAC address of the bridge
Root Path Cost - Path Cost to the Designated Root for this MST instance.
Root port - Port to access the Designated Root for this MST instance.
Command Buttons
Apply - Applies the new configuration and causes the changes to take effect. These changes will not
be retained across a power cycle unless a save configuration is performed.
2011 Fujitsu Technology Solutions
©