Fujitsu PRIMERGY BX900 User Manual page 474

Blade server systems ethernet connection blade module sb6 / sb11a / sb11 switch version
Hide thumbs Also See for PRIMERGY BX900:
Table of Contents

Advertisement

10.4.10.2
show lacp interface
This command displays a summary of LACP states for a specific interface or all interfaces.
Syntax
show lacp interface {<slot/port> | all}
Default Setting
None
Command Mode
Privileged Exec
Display Message
Intf: Display interface number.
Role: Role played by the interface. It can be one of the following:
Actor: Local device participating in LACP negotiation.
Partner: Remote device participating in LACP negotiation.
Exp: Expired state. Yes indicates the actor or partner is in an expired state. No indicates the actor or
partner is not in an expired state.
Def: Default. Yes indicates that the actor's receive machine is using the default operational partner
information, administratively configured for the partner. No indicates the operational partner
information in use has been received in an LACP PDU.
Dist: Distribution of outgoing frames. No indicates distribution of outgoing frames on the link is
currently disabled and is not expected to be enabled. Otherwise, the value is Yes.
Col: Collection of incoming frames.Yes indicates collection of incoming frames on the link is
currently enabled and is not expected to be disabled. Otherwise, the value is No.
Syn: Synchronization. If the value is Yes, the link is considered "in synch". It has been allocated to
the correct link aggregation group, the group has been associated with a compatible aggregator, and
the identity of the link aggregation group is consistent with the system ID and operational key
information transmitted. If the value is No, the link is currently "out of synch", not in the right
aggregation
Aggr: Ability of aggregation port to Aggregate (Yes) or to operate only as an individual link (No).
Timeout: LACP timeout preference. Periodic transmissions of LACP PDUs occur at either a slow or
fast transmission rate, depending upon the expressed LACP timeout preference (Long Timeout or
Short Timeout).
Activity: Actor or partner's port activity. Passive indicates the port's preference for not transmitting
LAC PDUs unless its partner's control value is Active. Active indicates the port's preference to
participate in the protocol regardless of the partner's control value.
2011 Fujitsu Technology Solutions
©
472

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy bx400

Table of Contents