Each of the three fan units cools an overlapped area in the hub covering 8 slots.
The slots covered by each fan unit are:
These 3 areas have their own temperature sensors. Also, integrated into each
fan unit is a sensor that detects a stopped or slow fan condition.
The Controller module continually monitors all the sensors via the SCI. You can
display the status of the fans and the temperature of the 8260, using the
following DMM command:
SHOW HUB
An example of the output from this command is shown in Figure 61.
Figure 61. Output from Show Hub Command
92
8260 Multiprotocol Intelligent Switching Hub
Fan 1 - slots 1-8
Fan 2 - slots 6-13
Fan 3 - slots 10-17
Hub Information:
Hub Type: 58G5801
Backplane Information:
Backplane Type
--------------
Load-Sharing Power Distribution Board
Enhanced TriChannel Backplane
Ring Backplane
Power Supply Information:
Power Supply
Status
------------
------
1
OKAY
2
OKAY
3
OKAY
4
REMOVED
Temperature Information:
Probe
Location
-----
--------
1
FAN_1
2
FAN_2
3
FAN_3
Fan Information:
Fan
Status
---
------
1
OKAY
2
OKAY
3
OKAY
8260>
Revision
--------
0
0
0
Model Number
------------
6000PS
6000PS
6000PS
Temperature
-----------
27 Degrees Celsius
29 Degrees Celsius
27 Degrees Celsius