Establishing a Telnet session in a command-line window
You can access the switch module by IP-enabled devices that are connected to the blade server
chassis management module. An Ethernet connection to the management-module external ports on
the blade server chassis is required. For more information, see the following documents on the
Resource CD:
•
Bade server chassis Installation and User's Guide
•
Blade server chassis Management Module User's Guide
•
Blade server chssis Management Module Installation Guide
To establish a Telnet session through a command-line window, complete the following steps:
Note: The IP addresses in these commands are the default IP addresses of the switch module.
1. Open a command-line window on the network-management workstation.
2. Type one of the following commands and press Enter.
For the switch module in I/O bay 3:
telnet 192.168.70.129
For the switch module in I/O bay 4:
telnet 192.168.70.130
A Telnet command-prompt window opens.
3. At the Login prompt, type the initial default user name, USERID, and press Enter. At the
Password prompt, type the initial default password, PASSW0RD (the sixth character is a zero,
not the letter O). The user name and password are case sensitive.
4. If you are accessing the switch module for the first time, press Enter to change the switch
passwords. You are prompted for a password for the root, factory, and user accounts.
A Telnet password-change window opens.
21