Using The Show Hub Command; Using The Show Power Mode Command - IBM Nways 8260 Manual

Multiprotocol intelligent switching hub
Table of Contents

Advertisement

8260> show hub
Hub Information:
Hub Type: 58G5801
Power Supply Information:
Power Supply
Status
------------
------
1
NORMAL
2
NORMAL
3
FAULTY
4
REMOVED
Temperature Information:
Probe
Location
-----
--------
1
FAN_1
2
FAN_2
3
FAN_3
Fan Information:
Fan
Status
---
------
1
OKAY
2
OKAY
3
OKAY
Figure 56. Using the SHOW HUB Command
Show Power Mode
The show power mode command was used to show the current power mode.
In this scenario, after taking one power supply down, we still had enough
power to support all the installed modules; therefore the hub remained in
fault tolerant mode.
8260> show power mode
Power Management Information
----------------------------
Hub Power Modes:
Fault-Tolerant Mode:
Fault-Tolerant Status:
Overheat Power Down Mode:
Figure 57. Using the SHOW POWER MODE Command
A Power Failure - Scenario 2
If a power supply should fail and there is not enough power to keep the 8260
in the fault-tolerant mode, you will receive a message informing you that the
Temperature
-----------
25 Degrees Celsius
25 Degrees Celsius
25 Degrees Celsius
FAULT_TOLERANT
FAULT_TOLERANT
DISABLE
Chapter 5. 8260 Intelligent Power Management Subsystem
87

Advertisement

Table of Contents
loading

Table of Contents