When designing an Ethernet segment consisting of the 8260 Ethernet 10-Port
10Base-FB Module, you must use the following Equivalent Distances for this
module:
114
8260 Multiprotocol Intelligent Switching Hub
information about the Ethernet security card, please refer to 7.11, "8260
Ethernet Security Daughter Card" on page 121.
Support for port redundancy
You can set up redundancy between two links on the same module or two
different modules. Note that port redundancy is supported between different
types of modules. For example, you can set a 10Base-T port on an 8260
Ethernet 24-Port 10Base-T Module to be a redundant port for a 10Base-FB
port on the 8260 Ethernet 10-Port 10Base-FB Module.
Table 22. Equivalent Distances for Ethernet 10Base-FB Module
8260 Module
24-port 10Base-T Module
Incoming signal to TP port
Outgoing signal to TP port
Equivalent Distance (meters)
190
140
50