Dual Fiber Repeater Module Side View - IBM Nways 8260 Manual

Multiprotocol intelligent switching hub
Table of Contents

Advertisement

Table 31 (Page 2 of 2). Dual Fiber Repeater Module LED Descriptions
LED Name
RI/RO
JA1 and JA2
Port Status
Figure 114 shows the side view of the dual fiber repeater module. As can be
seen, in addition to the 11 isolated segments and the mounting for one T-MAC,
there is an 8-position DIP switch located on the module. These DIP switches are
used in the absence of an installed management module in the 8260. However,
if a management module is installed in your 8260, the setting of these DIP
switches will be ignored unless DIP_CONFIGURATION is enabled for DMM. For
more information, please refer to 4.2.4.4, " Configuring DMM Device" on
page 50.
Figure 114. Dual Fiber Repeater Module Side View
The DIP switch settings on this module are identical to those of the 18-port active
per-port switching module which is described in 9.3.1, "Configuring the 18-Port
Active Per-Port Switching Module" on page 177.
Color
State
Green
On
Off
Blinking
Green
On
Off
Blinking
Green
On
Off
1 blink
Chapter 9. 8260 Token-Ring Modules
Description
Trunk enabled and operating
Trunk disabled.
Trunk enabled but not
operating normally
JADC card installed and
operating normally
JADC card not installed
JADC card failed diagnostics
Port enabled and operating
normally on the ring
Port disabled
Port enabled, no phantom
187