2. When the first two bin locations are displayed, enter the 2-digit bin
number (01–10) of the bin to be programmed.
3. Enter the deny code:
[0–9], [ ], [#] = Corresponding deny digits numbers
MUTE = Do Not Care digit
4. Press the HOLD button to save the entry. A confirmation tone is heard
and the display now updates.
5. When all entries for one table are complete, press the flexible button
for the next table.
Erasing a Bin Number
1. Enter a valid bin number.
2. Press the HOLD button.
Description
Each Deny Table contains ten bin numbers. Each bin number may be up
to eight-digits including {Do Not Care} digits. Entries in the Deny Table
represent numbers or codes that are to be denied or restricted. Common
entries would be [1] for restricting all [1+] type of calls. Exceptions to this
restriction would be entered into the Allow Table.
Deny Table A is referenced and searched only after the Allow Table A
is checked when Station COS is 2 and CO Line COS is either 1 or 2.
Deny Table B is referenced and searched only after the Allow Table B
is checked when Station COS is 3 and CO Line COS is either 1 or 3.
When Station COS is 4 and CO Line COS is 1, both allow tables are
looked at first (Allow Table A first, then Allow Table B) then both deny
tables (Deny Table A first, then Deny Table B).
- Do Not Care digits specify that the system should consider any digit
dialed in that position as a match. Do Not Care digits should not be
entered as the last digit in an entry.
- Search Special Table commands cannot be entered into the Deny
tables.