:POD Commands
:POD<n>:THReshold
Command Syntax
:POD<n>:THReshold <type>[<suffix>]
<n> ::= An integer, 1, is attached as a suffix to the command and
<type> ::= {CMOS | ECL | TTL | <user defined value>}
<user defined value> ::= -8.00 to +8.00 in NR3 format
<suffix> ::= {V | mV | uV}
POD1 ::= D0-D7
TTL ::= 1.4V
CMOS ::= 2.5V
ECL ::= -1.3V
The :POD<n>:THReshold command sets the threshold for the specified
group of channels. The threshold is used for triggering purposes and for
displaying the digital data as high (above the threshold) or low (below the
threshold).
This command is only valid for the MSO models.
N O T E
Query Syntax
:POD<n>:THReshold?
The :POD<n>:THReshold? query returns the threshold value for the
specified group of channels.
Return Format
<threshold><NL>
<threshold> ::= Floating point number in NR3 format
See Also
Example Code
414
(see
page
790)
defines the group of channels that are affected by the command.
"Introduction to :POD<n> Commands"
":DIGital<d>:THReshold"
":TRIGger[:EDGE]:LEVel"
' THRESHOLD - This command is used to set the voltage threshold for
' the waveforms.
There are three preset values (TTL, CMOS, and ECL)
' and you can also set a user-defined threshold value between
' -8.0 volts and +8.0 volts.
'
' In this example, we set channels 0-7 to CMOS, and then set the
' external trigger to TTL.
' thresholds for the channels you will be using in your program.
' Set channels 0-7 to CMOS threshold.
myScope.WriteString ":POD1:THRESHOLD CMOS"
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
on page 411
on page 249
on page 603
Of course, you only need to set the

Advertisement

Table of Contents
loading

Table of Contents