Medalist i3070 System Installation
Tools
Required, 1-2
Getting
Started, 1-3
Setting Up the Support Arm with Monitor, Keyboard,
and
Mouse, 1-4
Setting Up the Strip
Printer, 1-15
Preparing the
Testhead, 1-16
Powering the PDU and
Controller, 1-19
Installing a Support Bay and Instrument
Enabling the
Testhead, 1-25
Verifying the Vacuum
Subsystem, 1-28
Verifying the
Testhead, 1-32
Completing the
Installation, 1-33
In Case of
Difficulty, 1-34
CAUTION
The Medalist In-circuit Test System should only
be installed by an Agilent-Authorized Service
Representative.
Testhead boot conflicts may occur if this system is
on a network with Medalist 3070 UNIX
controllers with IP addresses other than in the
10.3.112.XX series.
Rack, 1-21
CAUTION
The Medalist test development software requires
that decimals in the board file use a period (.) and
not any other character such as a comma. Make
use that Windows is set to use a period for
decimals. (Select Control Panel > Regional and
Language Options > Regional Options tab. Click
Customize; in the Numbers tab ensure that the
selected Decimal symbol is a period.)
1-1

Advertisement

loading

Summary of Contents for Agilent Technologies Medalist i3070

  • Page 1 Completing the Installation, 1-33 ■ Language Options > Regional Options tab. Click In Case of Difficulty, 1-34 ■ Customize; in the Numbers tab ensure that the selected Decimal symbol is a period.) © Agilent Technologies 2010 Medalist i3070 System Installation...
  • Page 2 Utility knife to open boxes ■ 7/16-inch and 9/16-inch, 3/8-inch square-drive ■ sockets 6-inch-long, 3/8-inch square-drive extension ■ 3/8-inch square-drive ratchet ■ Cordless drill – 14.4 Volt, 3/8-inch drill / driver kit ■ © Agilent Technologies 2010 Medalist i3070 System Installation...
  • Page 3 • a certificate of hardware address for the System Card, and • configuration printouts. The bag on the testhead cradle contains: ■ • a female quick-disconnect compressed air fitting, and • an Installation Kit (it contains various tools and parts). © Agilent Technologies 2010 Medalist i3070 System Installation...
  • Page 4 © Agilent Technologies 2010 Medalist i3070 System Installation...
  • Page 5 Powering the PDU and Controller on page 1-19. b Use a T20 Torx driver to remove the pod cover screws and then remove the pod cover. c Remove power to the PDU if connected. © Agilent Technologies 2010 Medalist i3070 System Installation...
  • Page 6 Install the pole mount assembly in the column. c Open the pod door (if installing on the right). Secure the pole mount assembly to the cradle with the screws and washers provided. © Agilent Technologies 2010 Medalist i3070 System Installation...
  • Page 7 Allen key. safety collar b Hold the support arm with both hands while moving it down onto the collar on the pole mount assembly. Tighten with the hand lever. hand lever © Agilent Technologies 2010 Medalist i3070 System Installation...
  • Page 8 & bolts Alternatively, you can attach the keyboard tray to the support arm first. Then flip the keyboard tray up before installing the support arm on the pole mount assembly. © Agilent Technologies 2010 Medalist i3070 System Installation...
  • Page 9 To position the mouse on the right, route the mouse and keyboard cables through the hole on the right side of the keyboard tray. (Do the opposite to position the mouse on the left.) © Agilent Technologies 2010 Medalist i3070 System Installation...
  • Page 10 It may be necessary to obtain a 8120-1763 power cord extension cable to connect power from the PDU to the video monitor. Route the power cable through the testhead cable trough. © Agilent Technologies 2010 Medalist i3070 System Installation 1-10...
  • Page 11 Bundle the cables neatly behind the testhead and secure with cable ties. 9 Install the barcode scanner (if applicable). Connect the barcode scanner cables as shown in Figure 1-2 and route the cable to the controller. © Agilent Technologies 2010 Medalist i3070 System Installation 1-11...
  • Page 12 Close the pod door. Replace the pod cover and use a T20 Torx driver to tighten the pod cover screws. Figure 1-2 Connect barcode scanner cables connect to controller keyboard extension cable connect to keyboard © Agilent Technologies 2010 Medalist i3070 System Installation 1-12...
  • Page 13 Setting Up the Support Arm with Monitor, Keyboard, and Mouse Figure 1-3 Rear of testhead Shipping bolt and bracket at one of these cable trough locations (on each side of testhead) © Agilent Technologies 2010 Medalist i3070 System Installation 1-13...
  • Page 14 Tighten the hand lever. NOTE Use both hands when moving the support arm: one hand to hold the arm and the other to push the monitor support backwards (Figure 1-4). © Agilent Technologies 2010 Medalist i3070 System Installation 1-14...
  • Page 15 2 Connect the pre-routed power and data cables. NOTE To install the strip printer on the left side, re-route the power and data cables through the testhead cable trough. © Agilent Technologies 2010 Medalist i3070 System Installation 1-15...
  • Page 16 1 Locate the footswitch and cable that are coiled on the front of the testhead cradle (Figure 1-5). 2 Unpack the footswitch and place it on the floor in front of the testhead. © Agilent Technologies 2010 Medalist i3070 System Installation 1-16...
  • Page 17 2 Choose the label that is of the correct language for the location and apply it over the English text that is silk-screened on the rear of the testhead near the compressed air connectors. © Agilent Technologies 2010 Medalist i3070 System Installation 1-17...
  • Page 18 RJ45 LAN cable NOTE The RJ45 coupler should be visible from the rear of the controller’s pod. It should not be necessary to remove the pod cover to attach the site LAN cable. © Agilent Technologies 2010 Medalist i3070 System Installation 1-18...
  • Page 19 AC cord. A shock hazard can arise if the AC input and the safety ground are not grounded to the same point. NOTE The PDU is not serviceable; if it is defective, it must be replaced. © Agilent Technologies 2010 Medalist i3070 System Installation 1-19...
  • Page 20 Instructions for network configuration can be found in System Administration in the on-line help. Log on to Complete the Installation Log on as calibrate, which allows system configuration and testing. The default password is Agilent1 © Agilent Technologies 2010 Medalist i3070 System Installation 1-20...
  • Page 21 (cabling no functional ports on the ASRU card. (See Figure 1-8 longer passes through a cable clamp panel in the for the ASRU card connectors.) testhead). © Agilent Technologies 2010 Medalist i3070 System Installation 1-21...
  • Page 22 Module Door Locking Bracket Vacuum Manifold Module 0 Module 2 Optional Support Bay Module 1 Module 3 Module Umbilical Cables GPIB Cable Clamp Panel Cable Aux Aux Aux Aux Aux Aux Aux Aux © Agilent Technologies 2010 Medalist i3070 System Installation 1-22...
  • Page 23 If multiple racks or bays are installed containing equipment needing GPIB control, connect the GPIB cabling as shown in Figure 1-9 page 1-24. If the cable connections fork, GPIB errors may occur. © Agilent Technologies 2010 Medalist i3070 System Installation 1-23...
  • Page 24 External Instruments Instrument Rack Controller in the Support Bay or Testhead Mainframe Mainframe DUT Supplies in the Instrument 1 Instrument 1 Support Bay or Instrument 2 Instrument 2 Testhead YES - 3070 © Agilent Technologies 2010 Medalist i3070 System Installation 1-24...
  • Page 25 1 Apply PDU power to the testhead: Switch on the green rocker switch on the PDU. 2 Boot the controller (if not already booted), then log on as calibrate (default password is Agilent1 © Agilent Technologies 2010 Medalist i3070 System Installation 1-25...
  • Page 26 No red LEDs should remain on. If the testhead Root Directory Environment Variable in System encounters boot errors, verify the file bootptab Administration. contains the unique hardware address of the control card. © Agilent Technologies 2010 Medalist i3070 System Installation 1-26...
  • Page 27 In a BT-BASIC window, compile the system config file by entering: msi btgetenv$ ("AGILENTICT_ROOT") & "/diagnostics/th1" compile "config"; testhead b Compile the standard config file by entering: msi btgetenv$ ("AGILENTICT_ROOT") & "/standard" compile "config" © Agilent Technologies 2010 Medalist i3070 System Installation 1-27...
  • Page 28 ■ Connect the Compressed Air, 1-30 ■ Check the Vacuum Actuation System, 1-30 ■ Troubleshooting, 1-31 ■ Figure 1-10 on page 1-29 to reference internal vacuum solenoids in a four-module testhead. © Agilent Technologies 2010 Medalist i3070 System Installation 1-28...
  • Page 29 Air Lines Jumper 4-Module Manifold E9946A Vacuum components shown above the dotted line Vacuum components below the dotted line are customer supplied Vacuum Source Pressure Gage 2-inch Vacuum Hose Manual Cut-off Valve © Agilent Technologies 2010 Medalist i3070 System Installation 1-29...
  • Page 30 1 controls vacuum 3 c At the prompt, alternately enter: relay 2 controls vacuum 2 relay 3 controls vacuum 1 • faon relay 4 controls vacuum 0 • faoff © Agilent Technologies 2010 Medalist i3070 System Installation 1-30...
  • Page 31 (can have hoses to which vacuum ports? be 0; 1; 2; 3; 0,1; 2,3; 0-3). With the testhead powered-up, look at the system ■ config file: $AGILENTICT_ROOT/diagnostics/th1/config © Agilent Technologies 2010 Medalist i3070 System Installation 1-31...
  • Page 32 3 From the Service Package - Level 1 menu, select Config. 5 Log out of DGN. 4 Select DGN Config. 5 Press function key F6 in the AutoAdjust menu to run AutoAdjust All. 6 Verify that there are no errors. © Agilent Technologies 2010 Medalist i3070 System Installation 1-32...
  • Page 33 It may be necessary to remove the pod cover to performance port access the hex-slot of the leveling foot. port 2 100 pin bsi 1 end performance port © Agilent Technologies 2010 Medalist i3070 System Installation 1-33...
  • Page 34 See System Administration in the on-line help. Vacuum Subsystem The Vacuum Subsystem in Troubleshooting in the on-line help. Additional Resources To contact Agilent technical support, go to www.agilent.com/find/contactus and select your country for the support phone numbers. © Agilent Technologies 2010 Medalist i3070 System Installation 1-34...