Error Signal Troubleshooting - SATO GY412 Operator's Manual

Hide thumbs Also See for GY412:
Table of Contents

Advertisement

Section 4: Troubleshooting

4.1 ERROR SIGNAL TROUBLESHOOTING

Warning icons will be displayed in the icon display area of the operator panel from the third to the fifth box.
Up to three warning icons can be displayed when detecting multiple warning messages simultaneously.
The printer will continue issuing the label while it is detecting a warning message.
No.
LCD Message
1
2
3
4
5
Page 4-2
LED
Buzzer
ON
1 long
Machine
LINE:
beep
error
Off
To clear
ERROR
error: Power
: On
OFF
ON
1 long
Flash ROM
LINE:
beep
error
Off
To clear
ERROR
error: Power
: On
OFF
ON
3 short
Overrun error
LINE:
beeps
To clear
Blinks
error: Power
ERROR
OFF
: On
ON
3 short
Overrun error
LINE:
beeps
To clear
Blinks
error: Power
ERROR
OFF
: On
ON
3 short
Framing
LINE:
beeps
error
Blinks
To clear
ERROR
error: Power
: On
OFF
Error
Trouble
Condition
1. Defective
board
1. Access
failure to
Flash ROM
2. Exceed-
ing maxi-
mum times of
writing to
Flash ROM.
1. Improper
communica-
tion settings
2. Improper
cable con-
nection
1. Improper
communica-
tion settings
2. Improper
cable con-
nection
1. Improper
communica-
tion settings
2. Improper
cable con-
nection
Solution
1. Board
replacement
1. Board
replacement
1. Adjust
communica-
tion settings
2. Connect
cable prop-
erly
1. Adjust
communica-
tion settings
2. Connect
cable prop-
erly
1. Adjust
communica-
tion settings
2. Connect
cable prop-
erly
GY412 Operator Manual