Commands
The commands used to review and set system power parameters are listed below.
For information about...
show inlinepower
set inlinepower threshold
set inlinepower trap
show port inlinepower
set port inlinepower
show inlinepower
Use this command to display system power properties.
Syntax
show inlinepower
Parameters
None.
Defaults
None.
Mode
Switch command, read‐only.
Example
This example shows how to display system power properties:
D2(su)->show inlinepower
Detection Mode
Unit
----
1
set inlinepower threshold
Use this command to set the power usage threshold.
Syntax
set inlinepower threshold usage-threshold
Parameters
threshold value
: auto
Status
Power(W)
------
--------
auto
480
Specifies a power threshold as a percentage of total system power usage.
Valid values are 11 to 100.
Consumption(W)
Usage(%)
--------------
--------
0.00
0.00
show inlinepower
Refer to page...
2-31
2-31
2-32
2-32
2-33
Threshold(%)
Trap
------------
----
80
enable
D-Series CLI Reference 2-31