show snmp notifyfilter

Use this command to display SNMP notify filter information, identifying which profiles will not 
receive SNMP notifications.
Syntax
show snmp notifyfilter [profile] [subtree oid-or-mibobject] [volatile |
nonvolatile | read-only]
Parameters
profile
subtree oid‐or‐
mibobject
volatile | 
nonvolatile | read‐
only
Defaults
If no parameters are specified, all notify filter information will be displayed.
Mode
Switch command, read‐only.
Usage
See "About SNMP Notify Filters" on page 5‐28 for more information about notify filters.
Example
This example shows how to display SNMP notify filter information. In this case, the notify profile 
"pilot1" in subtree 1.3.6 will not receive SNMP notification messages:
D2(su)->show snmp notifyfilter
--- SNMP notifyFilter information ---
Profile
Subtree
Filter type
Storage type
Row status

set snmp notifyfilter

Use this command to create an SNMP notify filter configuration. This identifies which 
management targets should NOT receive notification messages, which is useful for fine‐tuning the 
amount of SNMP traffic generated.
Syntax
set snmp notifyfilter profile subtree oid-or-mibobject [mask mask] [included |
excluded] [volatile | nonvolatile]
(Optional) Displays a specific notify filter.
(Optional) Displays a notify filter within a specific subtree.
(Optional) Displays notify filter entries of a specific storage type.
= pilot1
= 1.3.6
= included
= nonVolatile
= active
show snmp notifyfilter
D-Series CLI Reference 5-33