Set Macauthentication Portquietperiod; Clear Macauthentication Portquietperiod - Enterasys D2 D2G124-12P Cli Reference Manual

D-series ethernet switches
Table of Contents

Advertisement

set macauthentication portquietperiod

This sets the number of seconds following a failed authentication before another attempt may be 
made on the port.
Syntax
set macauthentication portquietperiod time port-string
Parameters
time
port‐string
Defaults
None.
Mode
Switch command, read‐write.
Example
This example sets port 1 to wait 5 seconds after a failed authentication attempt before a new 
attempt can be made:
D2(su)->set macauthentication portquietperiod 5 ge.1.1

clear macauthentication portquietperiod

This sets the quiet period back to the default value of 30 seconds.
Syntax
clear macauthentication portquietperiod [port-string]
Parameters
port‐string
Defaults
If a port‐string is not specified then all ports will be set to the default port quiet period.
Mode
Switch command, read‐write.
Example
This example resets the default quiet period on port 1:
D2(su)->clear macauthentication portquietperiod ge.1.1
Period in seconds to wait after a failed authentication. By default, this is 30 
seconds.
Specifies the ports for which the quit period is to be applied. For a detailed 
description of possible port‐string values, refer to "Port String Syntax Used 
in the CLI" on page 4‐1. 
(Optional) Specifies the ports for which the quiet period is to be reset. For a 
detailed description of possible port‐string values, refer to "Port String 
Syntax Used in the CLI" on page 4‐1. 