Clear Dot1X Auth-Config - Enterasys D2 D2G124-12P Cli Reference Manual

D-series ethernet switches
Table of Contents

Advertisement

Examples
This example shows how to enable reauthentication control on ports 
D2(su)->set dot1x auth-config reauthenabled true ge.1.1-3
This example shows how to set the 802.1X quiet period to 120 seconds on ports 
D2(su)->set dot1x auth-config quietperiod 120 ge.1.1-3

clear dot1x auth-config

Use this command to reset 802.1X authentication parameters to default values on one or more 
ports.
Syntax
clear dot1x auth-config [authcontrolled-portcontrol] [maxreq] [quietperiod]
[reauthenabled] [reauthperiod] [servertimeout] [supptimeout] [txperiod] [port-
string]
Parameters
authcontrolled‐
portcontrol
maxreq
quietperiod
reauthenabled 
reauthperiod 
servertimeout
supptimeout 
txperiod 
port‐string
Defaults
If no parameters are specified, all authentication parameters will be reset.
If port‐string is not specified, parameters will be set on all ports.
Mode
Switch command, read‐write.
Examples
This example shows how to reset the 802.1X port control mode to auto on all ports:
D2(su)->clear dot1x auth-config authcontrolled-portcontrol
This example shows how to reset reauthentication control to disabled on ports 
D2(su)->clear dot1x auth-config reauthenabled ge.1.1-3
(Optional) Resets the 802.1X port control mode to auto.
(Optional) Resets the maximum requests value to 2.
(Optional) Resets the quiet period value to 60 seconds.
(Optional) Resets the reauthentication control state to disabled (false).
(Optional) Resets the reauthentication period value to 3600 seconds.
(Optional) Resets the server timeout value to 30 seconds.
(Optional) Resets the authentication supplicant timeout value to 30 
seconds.
(Optional) Resets the transmission period value to 30 seconds.
(Optional) Resets settings on specific port(s). For a detailed description of 
possible port‐string values, refer to "Port String Syntax Used in the CLI" on 
page 4‐1.