Snmp Row Display Command - Cisco 15216 EDFA2 Operation Manual

Cisco systems optical network system operations guide
Table of Contents

Advertisement

Chapter 6
ASH Commands
sysORLastChange.0 =
sysORID.1 =
sysORID.2 =
sysORDescr.1 =
sysORDescr.2 =
sysORUpTime.1 =
sysORUpTime.2 =
ifNumber.0 =
ifIndex.300 =
ifIndex.302 =
ifIndex.350 =
ifDescr.300 =
ifDescr.302 =
ifDescr.350 =
ifType.300 =
ifType.302 =
ifType.350 =
ifMtu.300 =
ifMtu.302 =
ifMtu.350 =
ifSpeed.300 =
ifSpeed.302 =
ifSpeed.350 =
...

6.6.7 snmp row display Command

Command
snmp row display
Syntax Description
snmp row display {IP_address | local} row_name index
Displays a row. Use this command to obtain information to use with other commands. Type the
command, the first few letters of the attribute, and press Tab to view a list of attributes that can be set.
Type an attribute from the list to view its row data. See
Example 6-19 snmp row display Command
ash:hostname:ONS15216 EDFA2> snmp row display local cerent15216Edfa
ash:hostname:ONS15216 EDFA2> snmp row display local cerent15216EdfaCfgGroup
CLASS CERENT-MIB.cerent15216EdfaCfgGroup ::=
{
78-16033-01
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
135;
{ snmpBasicCompliance };
{ rs232Compliance };
"";
"";
355925;
355925;
3;
300;
302;
350;
"Intra-machine interface";
"Ethernet Interface";
"RS232 Interface";
softwareLoopback;
ethernetCsmacd;
rs232;
0;
1500;
0;
0;
10000000;
19171;
cerent15216EdfaCfgGroup
cerent15216EdfaPumpCfgEntry
cerent15216EdfaAlarmControl
cerent15216EdfaStatusGroup
cerent15216EdfaPumpStatusEntry
cerent15216EdfaAlarmEntry
cerent15216EdfaOpGroup
cerent15216EdfaCfgSaved =
cerent15216EdfaLpoutSetpoint =
cerent15216EdfaLpoutDeviation =
cerent15216EdfaLpoutHysteresis =
cerent15216EdfaLOSThreshold =
cerent15216EdfaLOSHysteresis =
Example
true;
1000;
200;
100;
-2400;
100;
Cisco ONS 15216 EDFA2 Operations Guide
SNMP Commands
6-19.
6-19

Advertisement

Table of Contents
loading

Table of Contents