Rtrv-Th-Eqpt; Table 9-47 Rtrv-Th-Env Syntax Description - Cisco 15216 EDFA2 Operation Manual

Cisco systems optical network system operations guide
Table of Contents

Advertisement

Chapter 9
TL1 Commands
Example 9-43 RTRV-TH-ENV Command and Response
Amp01:ONS15216 EDFA2> RTRV-TH-ENV:Amp01:ALL:123::PWRBUSMIN;
Amp01 2002-07-16 14:24:29
M
123 COMPLD
"PWR-A,ENV:PWRBUSMIN,,,420"
;

Table 9-47 RTRV-TH-ENV Syntax Description

Parameter
date
time
aid
threshholdtype
and
thresholdvalue
pairs

9.7.41 RTRV-TH-EQPT

Command
RTRV-TH-EQPT
Retrieves general threshold values for the ONS 15216 EDFA2.
Syntax
RTRV-TH-EQPT:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,];
<sid> <date> <time>
M
<ctag> COMPLD
"<aid>:<thresholdtype>,,,<thresholdvalue>"
;
78-16033-01
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Syntax
yyyy-mm-dd
hh:mm:ss
PWR-A
PWR-B
ALL
PWRBUSMIN
PWRBUSMAX
Description
Date of origination of TL1 message.
Time of origination of TL1 message.
PWR-A, PWR-B, and ALL have same input effect.
Affecting Power Bus A (or both A and B).
Affecting Power Bus B.
Any or all of the preceding (command input only).
Type of threshold that is to be retrieved. A null value is
equivalent to ALL. Possible to specify values for one or more
of the following:
Power bus minimum voltage
(cerent15216EdfaPowerBusDCVoltageMin).
thresholdvalue can be between 350 and 700, with default of
400, in units of –10 VDC.
Power bus maximum voltage
(cerent15216EdfaPowerBusDCVoltageMax).
thresholdvalue can be between 350 and 700, with default of
570, in units of –10 VDC.
Cisco ONS 15216 EDFA2 Operations Guide
TL1 Commands and Autonomous Messages
9-57

Advertisement

Table of Contents
loading

Table of Contents