Chapter 9
TL1 Commands
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Table 9-23 INH-MSG-ALL Syntax Description (continued)
Parameter
condtype
78-16033-01
Syntax
LOS
GAIN
LPOUT
CTMP
LCRNT1
LCRNT2
LTMP1
LTMP2
POWERBUSA
POWERBUSB
CTRLMODE1
CTRLMODE2
TL1 Commands and Autonomous Messages
Description
Condition type of the alarm or event that is to be
inhibited (maps to cerent15216EdfaLogEventID). ALL
maps to all types. A null maps to none of the types, i.e.,
with a null, all existing condtype allowances are kept
unchanged. Possible condtype and corresponding
conddescr (in quotes) are:
"Loss of Signal" (input power) alarm
(cerent15216EdfaAlarmLpin).
"Gain Out of Range" alarm
(cerent15216EdfaAlarmGain).
"Loss of Output Power" alarm
(cerent15216EdfaAlarmLpout).
"Case Temperature Out of Range" alarm
(cerent15216EdfaAlarmCtmp).
"Excessive Pump1 Current" alarm
(cerent15216EdfaAlarmLcrnt1).
"Excessive Pump2 Current" alarm
(cerent15216EdfaAlarmLcrnt2).
"Excessive Pump1 Temperature" alarm
(cerent15216EdfaAlarmLtmp1).
"Excessive Pump2 Temperature" alarm
(cerent15216EdfaAlarmLtmp2).
"Power Bus A (voltage) Alarm"
(cerent15216EdfaAlarmPowerBusA).
"Power Bus B (voltage) Alarm"
(cerent15216EdfaAlarmPowerBusB).
"Pump1 Control Mode Changed"
(cerent15216EdfaControlMode for
cerent15216EdfaPumpCfgPumpNumber=1).
"Pump2 Control Mode Changed"
(cerent15216EdfaControlMode for
cerent15216EdfaPumpCfgPumpNumber=2).
Cisco ONS 15216 EDFA2 Operations Guide
9-23