Ed-Dwdm; Table 9-17 Ed-Dwdm Syntax Description - Cisco 15216 EDFA2 Operation Manual

Cisco systems optical network system operations guide
Table of Contents

Advertisement

Chapter 9
TL1 Commands

9.7.10 ED-DWDM

Command
ED-DWDM
Configures the ONS 15216 EDFA2 optical control parameters.
Syntax
ED-DWDM:[<tid>]:<aid>:<ctag>:::[PUMP1CTRLMODE=<pump1ctrlmode>],[PUMP1CTRLVALUE=<pump1ctrlv
alue>],[PUMP2CTRLMODE=<pump2ctrlmode>],[PUMP2CTRLVALUE=<pump2ctrlvalue>],[OVERALLGAIN=<gai
n>],[PREATT=<preatt>];
Example 9-12 ED-DWDM Command
Amp01:ONS15216 EDFA2> ED-DWDM:Amp01:ALL:123:::PUMP1CTRLMODE=GAINTEMP;

Table 9-17 ED-DWDM Syntax Description

Parameter
aid
pump1ctrlmode,
pump2ctrlmode
78-16033-01
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Syntax
1
ALL
GAINTEMP
OPWR
CRNT
PWR
IDLE
Description
1 and ALL have same input effect.
Pump 1 or pump 2 control mode (maps to
cerent15216EdfaPumpCfgControlMode for the corresponding
pump). Generally, pump1ctrlmode and pump2ctrlmode must be
the same value. One exception is OPWR which is not valid for
pump 1 and can only be set for pump 2. Possible values are:
Constant Gain Temperature Compensated mode (manufacturer
default) (cerent15216EdfaPumpCfgControlMode set to
constGainTempComp). If one pump is set to GAINTEMP, the
other pump automatically gets set to GAINTEMP also.
Constant Output Power mode
(cerent15216EdfaPumpCfgControlMode set to
constOutputPower). This is not a valid mode for pump 1. If
pump 2 is set to OPWR, pump 1 gets automatically set to PWR
with a value of 75 mW.
Constant Pump Current mode
(cerent15216EdfaPumpCfgControlMode set to constCurrent).
Must set pump 1 and pump 2 to this mode at the same time.
Constant Pump Power mode
(cerent15216EdfaPumpCfgControlMode set to constPower).
Must set Pump 1 and Pump 2 to this mode at the same time.
Pump is shut down (cerent15216EdfaPumpCfgControlMode
set to idle).
Cisco ONS 15216 EDFA2 Operations Guide
TL1 Commands and Autonomous Messages
9-17

Advertisement

Table of Contents
loading

Table of Contents