9.7.40 RTRV-TH-ENV

Command
RTRV-TH-ENV
Retrieves threshold values of the environmental (power bus) parameters of the ONS 15216 EDFA2.
Syntax
RTRV-TH-ENV:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,];
<sid> <date> <time>
M
<ctag> COMPLD
"<aid>,ENV:<thresholdtype>,,,<thresholdvalue>"
;
Cisco ONS 15216 EDFA2 Operations Guide
9-56
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Syntax
LOSHYST
LOSTH
LPOUTDEV
LPOUTHYST
LPOUTSETPT
Description
Type of threshold or set point that is to be retrieved. A null
value is equivalent to ALL. Possible to specify values for one
or more of the following:
Loss of signal (input power) hysteresis
(cerent15216EdfaLOSHysteresis).
thresholdvalue can be between 0 and 1000, with default of 100,
in units of 100 dB.
Loss of signal (input power) threshold
(cerent15216EdfaLOSThreshold).
thresholdvalue can be between –3100 and –1500, with default
of –3000, in units of 100 dBm.
Loss of output power deviation
(cerent15216EdfaLpoutDeviation).
thresholdvalue can be between 0 and 1000, with default of 200,
in units of 100 dB.
Loss of output power hysteresis
(cerent15216EdfaLpoutHysteresis).
thresholdvalue can be between 0 and 1000, with default of 100,
in units of 100 dB.
Loss of output power set point
(cerent15216EdfaLpoutSetpoint). This read-only value is only
valid when amplifier is in Constant Output Power (OPWR) and
Constant Pump Power (PWR) modes. Can be disregarded when
in Constant Gain Temperature Compensated (GAINTEMP) or
Constant Pump Current (CRNT) mode.
thresholdvalue is read-only and automatically determined by
the pump control mode with a possible value between 0 and
1000 in units of 10 mW.