F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Table 8-1
Attribute
MAXCTMP
MAXCTMPHYST Maximum
MINCTMP
78-16033-01
Alarm Threshold Attribute Definitions (continued)
Variable
Definition
Syntax
Maximum
Integer
case
(20 to 70)
temperature
Integer
case
(0 to 10)
temperature
hysteresis
Minimum
Integer
case
(–10 to 10)
temperature
Maximum
Access
Description
Read-write Alarm notifies operations personnel if
the case temperature of the
ONS 15216 EDFA2 is at a level that
may impact proper operation of the
optical network. Set the maximum
case temperature at a value that is
appropriate for intended application
and within product specifications.
Consult with the Cisco TAC to
determine the correct value for your
application. As a guideline, Cisco
recommends that maximum case
temperature value be set at 50
entries are between 20 and 70
Read-write Used to set the amount that the case
temperature of module must drop
below the maximum case temperature
alarm level before the alarm is cleared.
Set the hysteresis at a value that is
appropriate for the application so that
the alarm condition clears when the
input is stable. Consult with the Cisco
TAC to determine the correct value for
your application. As a guideline, Cisco
recommends setting the value at 1
Valid entries are between 0 and 10
Setting this value to 0 disables this
option.
Read-write Alarm notifies operations personnel if
the case temperature of the
ONS 15216 EDFA2 drops below a
level that impacts proper operation of
the optical network. The minimum
case temperature should be set at a
value that is appropriate for the
intended application and within
product specifications. Consult with
the Cisco TAC to determine the correct
value for your application. As a
guideline, Cisco recommends that
minimum case temperature be set at
°
1
C. Valid entries are between –10 and
°
10
C.
Cisco ONS 15216 EDFA2 Operations Guide
Set Alarm Thresholds
°
C. Valid
°
C.
°
C.
°
C.
8-9