Chapter 4
Provisioning Using ASH and SNMP
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Table 4-1
Attribute
cerent15216Edfa
CtmpMax
cerent15216Edfa
CtmpMaxHystere
sis
78-16033-01
Alarm Threshold Attribute Definitions (continued)
Variable
Definition
Syntax
Maximum
Integer
case
(20 to 70,
temperature
65 default)
Maximum
Integer
case
(0 to 10,
temperature
1 default)
hysteresis
Maximum
Access
Description
Read-write Alarm notifies operations personnel if
the case temperature of the
ONS 15216 EDFA2 is at a level that may
impact proper operation of the optical
network. Set the maximum case
temperature at a value that is appropriate
for intended application and within
product specifications. Consult with the
Cisco TAC to determine the correct value
for your application. As a guideline,
Cisco recommends that maximum case
temperature value be set at 50
entries are between 20 and 70
Read-write Used to set the amount that the case
temperature of module must drop below
the maximum case temperature alarm
level before the alarm is cleared. Set the
hysteresis at a value that is appropriate
for the application so that the alarm
condition clears when the input is stable.
Consult with the Cisco TAC to determine
the correct value for your application. As
a guideline, Cisco recommends setting
the value at 1
between 0 and 10
0 disables this option.
Cisco ONS 15216 EDFA2 Operations Guide
Set Alarm Thresholds
°
C. Valid
°
C.
°
C. Valid entries are
°
C. Setting this value to
4-9