Tables and Groups

5.4.4 OverallControl Table

The cerent15216EdfaOverallControl table allows the user to display and configure overall gain and
pre-attenuation.
Table 5-9
Variable
cerent15216EdfaConst
GainOverallGain
cerent15216EdfaVariab
leGainPreAttenuation

5.4.5 PumpStatusEntry Table

The cerent15216EdfaPumpStatusEntry table is used to display optical amplification module data.
Table 5-10

Table 5-10 cerent15216EdfaPumpStatusEntry Variable Descriptions

Variable
cerent15216EdfaPumpStatusPumpNum
cerent15216EdfaPumpStatusLaserChipTemp
cerent15216EdfaPumpStatusLaserChipTemp
Setpoint
cerent15216EdfaPumpStatusLaserTECCurre
nt
cerent15216EdfaPumpStatusLaserPower
cerent15216EdfaPumpStatusLaserCurrent
cerent15216EdfaPumpStatusAmbientTemp
Cisco ONS 15216 EDFA2 Operations Guide
5-18
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Table 5-9
describes cerent15216EdfaOverallControl variables.
cerent15216EdfaOverallControl Variable Descriptions
Syntax
Integer (130 to
220)
Integer (10 to
100)
displays information regarding the cerent15216EdfaPumpStatusEntry table variables.
Chapter 5
SNMP MIB Installation and Configuration
Maximum
Access
Description
Read-write
The overall gain (*10 dB) that is used when
the control mode in the PumpCfgEntry table
is set to constGainTempComp.
This variable is irrelevant in
constOutputPower, constCurrent, and
constPower modes.
Read-write
The pre-attenuation (*10 dB) that is used
when the control mode in the PumpCfgEntry
table is set to constOutputPower,
constCurrent, or constPower.
This variable is irrelevant in
constGainTempComp mode.
Maximum
Syntax
Access
cerent15216Ed
Read-only
faPumpNumber
Integer (–9999
Read-only
to 9999)
Integer (0 to
Read-only
999)
Integer (0 to
Read-only
99999)
Integer (0 to
Read-only
99999)
Integer (0 to
Read-only
999999)
Integer (–9999
Read-only
to 9999)
Description
Laser pump number
Laser chip
°
temperature (*10
C)
Laser chip
temperature setpoint
°
(*10
C)
Laser TEC current
(mA)
Laser power (*100
mW)
Laser current (*100
mA)
Ambient temperature
°
(*100
C)
78-16033-01