Table 9-48 Rtrv-Th-Eqpt Syntax Description - Cisco 15216 EDFA2 Operation Manual

Cisco systems optical network system operations guide
Table of Contents

Advertisement

TL1 Commands and Autonomous Messages
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Example 9-44 RTRV-TH-EQPT Command and Response
Amp01:ONS15216 EDFA2> RTRV-TH-EQPT:Amp01:ALL:123::MAXCTMP;
Amp01 2001-06-08 09:00:05
M
123 COMPLD
"EQPT:MAXCTMP,,,60"
;

Table 9-48 RTRV-TH-EQPT Syntax Description

Parameter
date
time
aid
threshholdtype
and
thresholdvalue
pairs
Cisco ONS 15216 EDFA2 Operations Guide
9-58
Syntax
Description
yyyy-mm-dd
Date of origination of TL1 message.
hh:mm:ss
Time of origination of TL1 message.
EQPT and ALL have same input effect.
EQPT
General parameters of the ONS 15216 EDFA2 (not directly
affecting optical signal or power bus).
ALL
Any or all of the preceding (command input only).
Type of threshold or set point that is to be retrieved. A null
value is equivalent to ALL. Possible to specify values for one
or more of the following:
MAXCTMP
Maximum case temperature (cerent15216EdfaCtmpMax).
thresholdvalue can be between 20 and 70, with default of 65 in
units of
MAXCTMPHYST
Maximum case temperature hysteresis
(cerent15216EdfaCtmpMaxHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in
units of
MINCTMP
Minimum case temperature (cerent15216EdfaCtmpMin).
thresholdvalue can be between –10 and 10, with default of –5,
in units of
MINCTMPHYST
Minimum case temperature hysteresis
(cerent15216EdfaCtmpMinHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in
units of
°
C.
°
C.
°
C.
°
C.